Service Manual

TestingtheTractionCircuitHydraulicPumpFlowandRelief
PressureTest(GreensPro1260)
g240223
Figure23
Thehydraulicpumpowtestisrecommendedtodeterminethetractioncircuit
performance.ThistestcomparesuidowataNoLoadwithuidowUnder
Load.Adropinowunderloadofmorethan12%indicatesaninternalleakor
malfunctioningreliefvalveinthehydraulicpump.Awornhydraulicpumpor
malfunctioningreliefvalveislessefcient.Eventually,enoughuidbypasswill
causetheunittostallunderheavyloadconditions.Continuedoperationcan
generateexcessiveheat,causedamagetosealsandothercomponentsinthe
hydraulicsystem,andaffectoverallmachineperformance.
SpecialEquipmentRequired:
Hydraulictesterwithowmeterwithpressuregaugewithaminimum45
lpm(12gpm)capacity.
Non-contacttachometer(phototach)
TestProcedure
1.EnsurethatthemotioncontrolpedalsarecorrectlyadjustedfortheNEUTRAL
position.Also,ensurethatthehydraulicpumpisatfullstrokewhenthe
motioncontrolpedalsaremovedtothefullforwardposition.
2.Parkthemachineonaclean,levelsurfacewiththetransportwheelsinthe
raisedandlockedposition,shutofftheengine,andengagetheparkingbrake.
CAUTION
Beforeopeningthehydraulicsystem,pressthemotioncontrol
pedalstoreleasethepressureinthesystemandavoidinjuryfrom
thepressurizedhydraulicuid.
GreensPro
1240/1260
Page5–25
HydraulicSystem:TestingtheHydraulicSystem
14211SLRevA