Operator's Manual

Code
LEDFlashPatternBehaviorDetails
MachineSpecicFaults
Connectornotpluggedin;locate
thelooseordisconnectedharness
connectorandconnectit.
Somethingwronginthewiring;
contactyourToroDistributor.
11Blinkonce,pause,blinkonce,long
pause,thenrepeat
LostcommunicationwithBASE.
BASEisbad;contactyourToro
Distributor.
12Blinkonce,pause,blinktwice,long
pause,thenrepeat
VersionincompatibilityoftheBASE
and/orHH
Wrongsoftware(installthecorrect
softwarefromTORODIAG);contact
yourToroDistributor.
13Blinkonce,pause,blink3times,long
pause,thenrepeat
WrongHH—notimplementedon
RevA
Wrongproductassociation(i.e.
tryingtoupdatesoftwareona
MH–400withaProPasshandheld)
ResettingtheFaultCode
Aftersolvingtheproblem,resetthefaultcodesbydisconnectingandreconnectingdiagnosticconnectors.The
diagnosticlightwillashcontinuouslyat1Hz(1ashpersecond).
ExitingDiagnosticMode
1.PushtheE-STOPbuttondowntoturnoffthepower;refertoE-Stopbutton(EHModel44954)(page17).
2.Disconnectthediagnostic,shuntconnectors.
3.Pushthetetheredcapontothe2diagnostic,shuntconnectors.
4.PulltheE-STOPuptoturnonthepower.
56