Troubleshooting
CheckingFaultCodes(EHModelsOnly)
IftheDiagnosticLEDindicatesthatthereisasystemfault,checkthefaultcodestodeterminewhatiswrong
withthemachine;refertoDiagnosticLEDFunction(EHModels)(page17).
EnteringDiagnosticModeandCheckingtheCodes
1.PushtheE-STOPbuttondowntoturnoffthepower.
2.Pullthetetheredcapfromthe2diagnostic,shuntconnectors(Figure64A).
3.Connectthediagnostic,shuntconnectorstogether(Figure64B).
g028876
Figure64
4.PulltheE-STOPuptoturnonthepower.
5.Countthenumberofashestodeterminethefaultcode,thenconsultthefollowingtable:
Note:Iftherearemultiplefaults,bothfaultswillash,thenalongpause,thentheashsequences
willrepeat.