MSDS

_____________________________________________________________________________________________
1116046 - Sealed Maintenance-Free Lead Acid Battery
Revision Date 03-Sep-2014
NTP (National Toxicology Program)
Known - Known Carcinogen
Reasonably Anticipated - Reasonably Anticipated to be a Human Carcinogen
OSHA (Occupational Safety and Health Administration of the US Department of Labor)
X - Present
Reproductive Toxicity
Product is or contains a chemical which is a known or suspected reproductive hazard.
Contains a known or suspected reproductive toxin.
Developmental Toxicity
Contains ingredients that have suspected developmental hazards. Inorganic lead
compounds can cause developmental damage.
STOT - single exposure
No information available.
STOT - repeated exposure
Causes damage to organs through prolonged or repeated exposure. Based on
classification criteria from the 2012 OSHA Hazard Communication Standard (29 CFR
1910.1200), this product has been determined to cause systemic target organ toxicity from
chronic or repeated exposure. (STOT RE).
Chronic Toxicity
Chronic exposure to corrosive fumes/gases may cause erosion of the teeth followed by jaw
necrosis. Bronchial irritation with chronic cough and frequent attacks of pneumonia are
common. Gastrointestinal disturbances may also be seen. Contains a known or suspected
carcinogen. Contains a known or suspected reproductive toxin. Possible risk of irreversible
effects. Avoid repeated exposure. Prolonged exposure may cause chronic effects. May
cause adverse effects on the bone marrow and blood-forming system. Lead compounds
may be absorbed by ingestion, by inhalation and through the skin. Lead may damage
kidney function, the blood forming system and the reproductive system.
Target Organ Effects
Respiratory system. Eyes. Skin. Gastrointestinal tract (GI). Reproductive System. Blood.
Central Nervous System (CNS). Gingival Tissue. Kidney. Teeth. Cardiovascular system.
Hematopoietic system. Immune system. May damage the unborn child.
_____________________________________________________________________________________________
Aspiration Hazard
No information available.
Numerical measures of toxicity Product Information
The following values are calculated based on chapter 3.1 of the GHS document
ATEmix (oral)
556.00 mg/kg
ATEmix (inhalation-gas)
6,429.00 ppm (4 hr)
ATEmix (inhalation-dust/mist)
1.20 mg/l
Page 9 / 13
ATEmix (inhalation-vapor)
16.00 ATEmix