SDS

Personal Protective Equipment advice is contained in Section 8 of the SDS.
SECTION 7 Handling and storage
Precautions for safe handling
Safe handling
Do not connect the positive terminal to the negative terminal with electrical wire or chain. Avoid polarity reverse connection when installing the
battery to an instrument. Do not wet the battery with water, seawater or acid; or expose to strong oxidizer. Do not damage or remove the external
tube. Keep the battery away from heat and fire. Do not disassemble or reconstruct the battery; or solder the battery directly. Do not give a
mechanical shock or deform. Do not use unauthorized charger or other charging method. Terminate charging when the charging process does
not end within specified time.
Use good occupational work practice. Observe manufacturer's storage and handling recommendations contained within this SDS.
Avoid physical damage to containers.
Other information
Keep dry.
Store under cover.
Protect containers against physical damage.
Observe manufacturer's storage and handling recommendations contained within this SDS.
Keep out of reach of children.
Store out of direct sunlight
Store away from incompatible materials.
Conditions for safe storage, including any incompatibilities
Suitable container
Store in original containers.
Storage incompatibility
Avoid reaction with oxidising agents
SECTION 8 Exposure controls / personal protection
Control parameters
Occupational Exposure Limits (OEL)
INGREDIENT DATA
Source
Ingredient
Material name
TWA
STEL
Peak
Notes
US ACGIH Threshold Limit
Values (TLV)
lithium
cobaltate
Cobalt and inorganic compounds, as Co
(Inhalable particulate matter)
0.02 mg/m3
Not
Available
Not
Available
Pulm func changes; BEI
US NIOSH Recommended
Exposure Limits (RELs)
graphite
Black lead, Mineral carbon, Plumbago,
Silver graphite, Stove black [Note: Also
see specific listing for Graphite
(synthetic).]
2.5 (resp)
mg/m3
Not
Available
Not
Available
Not Available
US OSHA Permissible Exposure
Levels (PELs) - Table Z3
graphite
Graphite
15 mppcf
Not
Available
Not
Available
(Name ((Natural)))
US OSHA Permissible Exposure
Levels (PELs) - Table Z1
graphite
Graphite, natural, respirable dust
Not Available
Not
Available
Not
Available
See Table Z-3
US ACGIH Threshold Limit
Values (TLV)
graphite
Graphite (all forms except graphite
fibers) (Respirable particulate matter)
2 mg/m3
Not
Available
Not
Available
Pneumoconiosis
US NIOSH Recommended
Exposure Limits (RELs)
copper
Copper metal dusts, Copper metal
fumes
1 mg/m3
Not
Available
Not
Available
[*Note: The REL also applies to
other copper compounds (as Cu)
except Copper fume.]
US OSHA Permissible Exposure
Levels (PELs) - Table Z1
copper
Copper: Dusts and mists (as Cu)
1 mg/m3
Not
Available
Not
Available
Not Available
US OSHA Permissible Exposure
Levels (PELs) - Table Z1
copper
Copper: Fume (as Cu)
0.1 mg/m3
Not
Available
Not
Available
Not Available
US ACGIH Threshold Limit
Values (TLV)
copper
Copper Dusts and mists, as Cu
1 mg/m3
Not
Available
Not
Available
Irr; GI; metal fume fever
US ACGIH Threshold Limit
Values (TLV)
copper
Copper Fume, as Cu
0.2 mg/m3
Not
Available
Not
Available
Irr; GI; metal fume fever
US NIOSH Recommended
Exposure Limits (RELs)
aluminium
Aluminium, Aluminum metal, Aluminum
powder, Elemental aluminum
10 (total), 5
(resp)
mg/m3
Not
Available
Not
Available
Not Available
US OSHA Permissible Exposure
Levels (PELs) - Table Z1
aluminium
Aluminum, metal (as Al): Total dust
15 mg/m3
Not
Available
Not
Available
Not Available
US OSHA Permissible Exposure
Levels (PELs) - Table Z1
aluminium
Aluminum, metal (as Al): Respirable
fraction
5 mg/m3
Not
Available
Not
Available
Not Available
US ACGIH Threshold Limit
Values (TLV)
aluminium
Aluminum metal and insoluble
compounds (Respirable particulate
matter)
1 mg/m3
Not
Available
Not
Available
Pneumoconiosis; LRT irr;
neurotoxicity
US NIOSH Recommended
Exposure Limits (RELs)
nickel
Nickel metal: Elemental nickel, Nickel
catalyst
0.015 mg/m3
Not
Available
Not
Available
Ca See Appendix A [*Note: The
REL does not apply to Nickel
carbonyl.]
US OSHA Permissible Exposure
Levels (PELs) - Table Z1
nickel
Nickel, metal and insoluble compounds
(as Ni)
1 mg/m3
Not
Available
Not
Available
Not Available
US ACGIH Threshold Limit
Values (TLV)
nickel
Nickel and inorganic compounds
including Nickel subsulfide, as Ni:
Elemental (Inhalable particulate matter)
1.5 mg/m3
Not
Available
Not
Available
Dermatitis; pneumoconiosis
Chemwatch:
5351-42
Version No:
6.1.1.1
Page
4
of
15
Toro Lithium Ion Battery [60V, 40V, 24V, 20V]
Issue Date:
13/10/2020
Print Date:
13/10/2020
Continued...