Operator's Manual

4
2. Turn unit on.
3. Swing unit slowly back and forth over leaves to be vacuumed.
Do not force tube into pile of debris.
IMPORTANT
This unit is designed to pick up and shred dry leaves and
other light, leafy debris.
Do not attempt to pick up stones, gravel, broken glass,
twigs, bark, acorns or pine cones as severe damage to fan
blades may result.
Do not tip vacuum tubes upright and for
ce feed debris into
tubes.
If the unit should start to vibrate or make abnormal noise, stop the
unit, unplug the cord and check for cause.
Emptying
Bag
1. Turn unit off. Disconnect extension cord.
2. Depress both tabs on bag collar to remove bag from unit
(Fig. 9).
3. Unzip bag and shake out debris.
Maintenance
Clogging
If the unit becomes clogged with debris, the obstruction can
usually be cleared by turning the unit off and then promptly
compressing the bag while it is still inflated, thereby forcing air
back out through the vacuum tubes. This reverse
airflow is usually
sufficient to dislodge most obstructions.
If the restriction cannot be cleared by compressing the bag, then
proceed with caution as follows:
1. Turn off and unplug unit.
2. Remove vacuum tubes.
3. Using a small stick or rod, carefully reach into impeller
opening and clear out debris.
Bag Cleaning
Do
not store debris in vacuum bag. Empty bag after each use. After
three uses, clean bag
thoroughly
.
T
urn bag inside out and shake out
dust and excess debris vigorously. Once a year, if necessary, wash
the bag by hand in soapy water.
POTENTIAL HAZARD
Under normal usage, the bag material is subject to
deterioration and wear.
WHAT CAN HAPPEN
Small objects could pass through a worn or damaged
bag and be thrown in direction of operator or
bystanders and cause serious personal injury.
HOW TO AVOID THE HAZARD
Check
bag fr
equently for wear or deterioration. If bag
is damaged, replace it with a genuine TORO part.
Impeller
Replacement
If
a loss of performance is detected while operating blower
,
unplug
unit, remove inlet cover, and check impeller blades for wear. If
blades are severely worn, see your Authorized TORO Service
Dealer for a new impeller.
Servicing Double-insulated
Appliance
In a double-insulated appliance, two systems of insulation are
provided instead of grounding. No grounding means is provided
on
a double-insulated appliance, nor should a
means for grounding
be added to the appliance. Servicing a double-insulated appliance
requires extreme care and knowledge of the system, and should be
done only by qualified service personnel. Replacement parts for a
double-insulated appliance must be identical to the parts they
replace. A double-insulated appliance is marked with the words
“DOUBLE INSULATION” or “DOUBLE INSULATED.” The
symbol (square within a square)
may also be marked on the
appliance.
Troubleshooting
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
Unit won’t run or stops running
1.
Unit not plugged in
1.
Plug in unit
2. On/of
f switch in “of
f” position
2. T
urn to “on”
3.
Inlet cover or vacuum tube incorrectly
installed or removed
3.
Secure cover or vacuum tube
4.
Blown fuse or tripped circuit breaker
4.
Replace fuse or reset
breaker
5.
Faulty extension cord
5.
Replace cord
Unit seems to be low on power
1.
Impeller is worn
1.
Replace impeller
V
acuum tube will not stay securely
fastened to housing
1.
Mounting tabs on tube are not fully
secured in housing
1.
Reposition vacuum tube to
proper position