Operator's Manual

Controls
Becomefamiliarwithallthecontrols(Figure7andFigure15)
beforeyoustarttheengineandoperatethemachine.
ControlPanel
STOP
!
!
G018909
7
13
12
11
10
9
8
5
4
32
6
1
Figure7
1.Keyandkeyswitch8.Right,traction-control
(forward/reverse)
2.Information9.Left,traction-control
(forward/reverse)
3.Engine—stop10.Emergency-stopbutton
4.Engine—run11.Modeswitch
(remote-controlmode|
manualmode)
5.Engine—start12.Vibration-directionswitch
(forward|reverse)
6.LEDdisplay
13.Travel-speed/vibration
switch(fast|slow|
vibrationOn)
7.Engine-speedswitch(fast
|slow)
LEDDisplay
Locationandoperation:TheLEDdisplayislocated
onthecontrolpanel.Thedisplayisembeddedintothe
electronicignitioncontrolblock,andiscontrolledthrough
themicroprocessor.Thedisplayprovidestheoperatoror
mechanicoperatinginformationaboutthesystemsonthe
machine.Thefollowingsectiondescribestheinformation
showninthedisplay.
Displaywhilestarting-up—voltage:Duringengine
start-up,thedisplayshowsthebatteryvoltagelevel.Rotatethe
keyswitchtotheStartpositiontodisplaythebatteryvoltage.
Displaywhilerunningthemachine—rpm:Whenthe
engineisrunning,thedisplayshowstheenginerpm.After
startingthemachine,thekeyswitchwillrotatebackto
engine-runpositionandtheenginerpmisindicatedinthe
display.
Displaywhenthekeyswitchisintheinformation
position—hourmeter—faults/warnings—software
version:Toviewoperationinformationforthemachine,
rotatethekeyswitchtotheinformationposition
(counterclockwisefromtheOffposition).
Hourmeter
Faultmessages
Faulthistory
Warnings
Softwareversion
Note:Operationinformationisstoredinnonvolatile
memory.Intheeventthatbatterypowerislost,this
informationremainsintact.Uponrestoringbatterypower,
thestoredoperationinformationisavailablefordisplay.
HourMeter
Thehourmeterdisplayindicatesthetotalnumberofhours
themachinehasrun.
RotatethekeyswitchtotheAccessorypositiontodisplay
thehourmeterinformation.
FaultMessages
Thefaultmessagesdenethesituationsthatcausetheengine
ofthemachinetoshutdownornotstart.Thesesafeguards
includeengineprotectcircuitsorothermachineprotection
devices.Faultmessageswillbeshownonthedisplayandwill
indicatewhateventhasshutdowntheengine.
Rotatethekeyswitchtotheinformationpositiontoviewthe
faultmessagesshouldtheyoccur.
LOWOIL—thismessagedisplayswhentheproperoil
pressureisnotachievedormaintained(monitoredbythe
oilpressureswitch).
CYLHEADTEMP—thismessagedisplayswhen
thetemperatureofthecylinderheadexceedsthesafe
operatingtemperature(monitoredbythetemperature
switchinthecylinderhead).
TILT—thismessagedisplayswhenthemachinetipangle
isexceeded(monitoredbythetipswitch).
ESTOP—thismessagedisplayswhentheemergency
stopbuttononthecontrolpanelisdepressed,andhas
notbeenreset(monitoredbytheemergencystopbutton
position).
Note:TheLEDdisplayalwaysindicatesthelastfault
messagethatoccurred.Thenonvolatilememoryinthe
microprocessoralwaysrequiresaninput,thereforethelast
messagewillbedisplayedevenafterthefaulthasbeen
corrected.
13