Operator's Manual

B.Placeawasteoilcontainerwitha57L(15US
gallons)capacityunderthedrainplugatthe
right-lowersideofthehydraulictank(Figure77).
G019150
2
4
1
3
Figure75
1.Hydraulictank3.Drainplug
2.Drain-plughole4.Waist-oilcontainer
C.Removethedrainplugandallowthehydraulic
uidtodrainintothecontainer(Figure77).
Note:Disposeoftheusedoilatacertied
recyclingcenter.
D.CleanthedrainplugandapplyPTFE
thread-sealingtapetothethreads.
E.Whenthehydraulicoilisdrainedfromthetank,
installthedrainpluginthedrainplughole,and
tighten(Figure77).
5.Fillthehydraulictankasfollows:
A.Fillthehydraulictankwithapproximately
49L(13USgallons)ofToroPremium
Transmission/HydraulicTractorFluidoran
equivalent;refertoHydraulic-tankGauge(page
20).
B.Installthehydraulictankbreather/cap.
C.Starttheengineandletitrunfora1or2minutes.
D.Stoptheengineandcheckforhydraulicuidleaks.
E.Checkthehydraulicuidlevel.Ifnecessary,add
hydraulicuiduntiltheuidlevelindicatesa
6.35–12.5mm(0.25–0.50inch)airbubbleseenat
thetopofthesightgauge;refertoCheckingthe
HydraulicFluidLevel(page26).
6.Installtheright-sidepanel;refertoInstallingthe
Right-sidePanel(page57).
7.Closethebothhoods;referto
ClosingtheHood(page
25).
CheckingtheHydraulicLines
ServiceInterval:Every100hours—Checkthehydraulic
linesforleaks,loosettings,kinkedlines,
loosemountingsupports,wear,weather,
andchemicaldeterioration.(Repairall
damagedhydrauliclinesbeforeoperating
themachine.)
Every1,500hours/Every2years(whichevercomes
rst)—Replaceallmovinghydraulichoses.
WARNING
Hydraulicuidescapingunderpressurecan
penetrateskinandcauseinjury.Fluidinjectedinto
theskinmustbesurgicallyremovedwithinafew
hoursbyadoctorfamiliarwiththisformofinjury
organgrenemayresult.
Keepyourbodyandhandsawayfrompin
holeleaksornozzlesthatejecthighpressure
hydraulicuid.
Usecardboardorpapertondhydraulicleaks,
neveruseyourhands.
56