LubricatingtheShaft
ServiceInterval:Every40hours—Lubricatetheshaftwith
lithium-basedgrease.
Lubricatetheexibleshafttopreventdryspotsthatcause
overheating.
1.Disconnecttheexibleshaftfromthevibratorheadandthe
powerunit.
2.Removetheinnercoreandwipeitclean(Figure8A).
A
B
C
G021331
Figure8
3.Coatthecorewith1.5mm(1/16inch)oflithium-based
grease(Figure8B).
Note:Over-lubricatingthecorewillshortenthelifeofthe
shaft.
4.Installthecoreintotheshaftcasing(Figure8C).
5.Installtheshaftontothepowerunit.
6.Installtheheadontotheshaft.
Storage
1.Disconnecttheextensioncordfromthepowertool.
2.Disconnecttheexibleshaftfromthepowertool.
3.Wipeawayanyconcreteorothermaterialonthepowertool.
4.Examinetheextensioncordthoroughlyforsignsofwearor
damage.Replaceitifitiswornordamaged.
5.Examinethepowertoolthoroughlyforworn,loose,or
damagedparts.Torepairorreplaceparts,contactan
AuthorizedServiceDealerforassistance.
6.Storethepowertoolandtheextensioncordinaclean,dry
place.