ServicingtheEngineOil
CrankcaseCapacity:RP-1200D1.1liter(37oz)
CrankcaseCapacity:RP-1400D1.5liter(50.7oz)
Oiltype:APICD,CE,CF,CF-4,CG-4orhigher
Refertothetablebelowtodeterminethecorrectoilviscosity
fortheambientairtemperatureinwhichthemachineis
operated:
Figure20
1.Pull-starttemperature
range
2.Electric-starttemperature
range
ChangingtheEngineOil
ServiceInterval:Aftertherst25hours
Every100hours
WARNING
Oilmaybehotaftertheenginehasbeenrun,and
contactwithhotoilcancauseseverepersonalinjury.
Avoidcontactingthehotengineoilwhenyoudrain
it.
1.Stoptheengineandwaitforallmovingpartstostop.
2.Placeadrainpanunderthedrainplug(
Figure21).
Figure21
1.Drainplug
3.Removethedrainplug(Figure21).
Note:Youmayhavetotipthecompactorbackward
todraintheoil.
4.Whentheoilhasdrainedcompletely,replacetheplug.
Note:Disposeoftheusedoilatacertiedrecycling
center.
5.Removethedipstick(Figure6)andslowlypourthe
speciedquantityandtypeofoilintothellerhole.
6.Insertthedipstickandchecktheengineoillevel;refer
toCheckingtheEngine-OilLevel(page8).
7.Replaceandsecurethedipstick.
8.Wipeupanyspilledoil.
15