Operator's Manual

4.Releasetheparkingbrake.
5.Movethemotion-controlleversforward.
Note:Themachineshouldmoveforward.
Note:Ifthemachinedoesnotmoveforward,
refertoAdjustingtheParkingBrake(page31).
6.Engagetheparkingbrakeandshutoffthe
machine.
AdjustingtheParkingBrake
1.Removethefueltank;referto(page).
2.Insidetheleftsideofthecontroltower,adjust
thenutsuntilthecablesaretaught(Figure44).
g186011
Figure44
1.Cable
2.Nuts
3.Installthefueltank,crossbracket,andcushion.
HydraulicSystem
Maintenance
WARNING
Hydraulicuidescapingunderpressurecan
penetrateskinandcauseinjury.Fluidinjected
intotheskinmustbesurgicallyremoved
withinafewhoursbyadoctorfamiliarwith
thisformofinjury;otherwisegangrenemay
result.
Keepyourbodyandhandsawayfrom
pinholeleaksornozzlesthateject
high-pressurehydraulicuid.
Usecardboardorpapertondhydraulic
leaks;neveruseyourhands.
ServicingtheHydraulic
DriveSystem
Expansion-tankcapacity:1.4L(1.5USquarts)
Hydraulic-uidtype:Toro®HYPR-OIL™500
Important:Alwaysusethecorrecthydraulic
uid.Unspecieduidswilldamagethehydraulic
system.
Note:Manyhydraulicuidsarealmostcolorless,
makingitdifculttospotleaks.Areddyeadditivefor
thehydraulicsystemoilisavailablein0.67oz(20
ml)bottles.Onebottleissufcientfor4to6gal(15to
22L)ofhydraulicuid.OrderPartNo.44-2500from
yourauthorizedT orodistributor.
CheckingtheHydraulic-Fluid
LevelfortheDriveSystem
ServiceInterval:Beforeeachuseordaily
1.Parkthemachineonalevelsurface,move
themotion-controlleverstotheNEUTRAL-LOCK
position,engagetheparkingbrake,andlower
thehopper.
2.Shutofftheengine,andremovethekey.Allow
theenginetocool.
3.Openthecowl.
4.Usethesightwindowtochecktheuidlevelin
theexpansiontank(Figure45).
Note:Theuidlevelshouldbeatthellline
onthedecal.
31