Service Manual
HYDRAULIC SYSTEM
5-1Toro Z Master G3 3000/5000/6000 Series Service Manual 
5
Hydrostatic Pump Removal
Note:  Cleanliness is a key factor in a successful 
repair of any hydrostatic system. Thoroughly 
clean all exposed surfaces prior to any type 
of maintenance. Cleaning all parts by using 
a solvent wash and air-drying is usually 
adequate. As with any precision equipment, 
all parts must be kept free of foreign material 
and chemicals. Protect all exposed sealing 
areas and open cavities from damage and 
foreign material.
G3 UHT Transmission Replacement 
(2009 through 2011 models)
Note:  The following procedures cover replacing 
the left hand UHT Transmission. The same 
procedures can be followed to remove the 
right hand UHT Transmission.
G3 UHT Transmission Removal (2009 - 2011 
models)
1.  Position the machine on a level surface.
2.  Disengage the PTO, move the motion control levers 
to the neutral locked position and set the parking 
brake.
3.  Stop the engine, remove the key, and wait for all 
moving parts to stop before leaving the operating 
position.
4.  Remove the negative battery cable from the battery 
(Fig. 263).
  Fig. 263  PICT-8541a
5.  Raise the seat and remove the guard from above the 
UHT that is being replaced (Fig. 264).
  Fig. 264  PICT-8695a