Operator's Manual

1.DisengagethePTO,movethemotioncontrollevers
totheneutrallockedposition,andsettheparking
brake.
2.Stoptheengine,removethekey,andwaitforall
movingpartstostopbeforeleavingtheoperating
position.
3.Unlatchtheseatandtilttheseatup.
4.Firstdisconnectthenegativebatterycableand
groundwirefromthenegative(-)batteryterminal
(
Figure44).
5.Slidetheredterminalbootoffthepositive(red)
batteryterminal.Thenremovethepositive(red)
batterycable(Figure44).
Figure44
1.Battery
7.Washer(1/4inch)
2.Terminalboot
8.Locknut(1/4inch)
3.Positivebatterycable9.Batteryclamp
4.Negativebatterycable10.J-bolts
5.Groundwire11.Wingnut(1/4inch)
6.Bolt(1/4x3/4inch)
6.Removebothwingnuts(1/4inch)securingthe
batteryclamp(
Figure44).
7.Removethebattery.
InstallingtheBattery
1.Positionbatteryinthetraywiththeterminalposts
towardtheengine(Figure44).
2.First,installthepositive(red)batterycableto
positive(+)batteryterminal.
3.Theninstallthenegativebatterycableandground
wiretothenegative(-)batteryterminal.
4.Securethecableswith2bolts(1/4x3/4inch),
2washers(1/4inch),and2locknuts(1/4inch)
(Figure44).
5.Slidetheredterminalbootontothepositive(red)
batterypost.
6.SecurebatterywithJ-bolts,holddownclampand
2washers(1/4inch),and2wingnuts(1/4inch)
(
Figure44).
ChargingtheBattery
WARNING
Chargingthebatteryproducesgassesthatcan
explode.
Neversmokenearthebatteryandkeepsparksand
amesawayfrombattery.
Important:Alwayskeepthebatteryfullycharged
(1.265specicgravity).Thisisespeciallyimportant
topreventbatterydamagewhenthetemperatureis
below32°F(0°C).
1.Removethebatteryfromthechassis.
2.Chargebatteryfor10to15minutesat25to30amps
or30minutesat4-6amps.
3.Whenthebatteryisfullycharged,unplugthecharger
fromtheelectricaloutlet,thendisconnectthe
chargerleadsfromthebatteryposts(
Figure45).
Figure45
4.Installthebatteryinthemachineandconnectthe
batterycables;refertoInstallingtheBattery.
Note:Donotrunthemachinewiththebattery
disconnected,electricaldamagemayoccur.
ServicingtheFuses
Theelectricalsystemisprotectedbyfuses.Itrequires
nomaintenance,however,ifafuseblowscheck
component/circuitformalfunctionorshort.