Engine oil with a minimum rating of 55 SUS at
212 F° and an API classification of SH/CD is
recommended. A 20W-50 engine oil has been
selected for use by the factory and is
recommended for normal operating
temperatures.
Check oil level when cold. To check the
transaxle fluid level, remove the vent. Oil level
should be 1-7/8” - 2-3/16” (4.8 cm - 5.56 cm)
from the top of the vent port.
The oil level can only be checked when the
transaxle is removed from the machine.
0702-0501
0702-0502
Fluids