Service Manual

7-6
Digital Edition - TIMECUTTERĀ® HD Service Manual
April 2017
Table of Contents
HYDROSTATIC DRIVE SYSTEM
Tracking adjustment
If the unit tracks or pulls to the RIGHT:
Turn the LH adjustment nut 1 full turn CLOCKWISE. If more adjustment is needed, turn the adjustment nut 1 full
turn at a time (Figure 5).
If the unit tracks or pulls to the LEFT:
Turn the RH adjustment nut 1 full turn CLOCKWISE. If more adjustment is needed, turn the adjustment nut 1 full
turn at a time (Figure 5).
Figure 5