Operator's Manual

ServicingtheFuses
Theelectricalsystemisprotectedbyfuses.Itrequires
nomaintenance;however,ifafuseblows,checkthe
component/circuitforamalfunctionorshort.
Fusetype:
Main—F1(30A,blade-type)
ChargeCircuit—F2(25A,blade-type)
1.Removethescrewssecuringthecontrolpaneltothe
machine.
Note:Retainallfasteners.
2.Liftthecontrolpaneuptoaccessthemainwireharness
andfuseblock(Figure47).
3.Toreplaceafuse,pulloutonthefusetoremoveit
(Figure47).
30
25
30
25
G014921
2
1
g014921
Figure47
1.Main(30A)2.Chargecircuit(25A)
4.Returnthecontrolpaneltoitsoriginalposition.
Note:Usethescrewsremovedpreviouslytosecure
thepaneltothemachine.
DriveSystem
Maintenance
CheckingtheTirePressure
ServiceInterval:Every25hours—Checktirepressure.
Maintaintheairpressureinthefrontandreartiresas
specied.Uneventirepressurecancauseunevencut.Check
thepressureatthevalvestem(Figure48).Checkthetires
whentheyarecoldtogetthemostaccuratepressurereading.
Refertothemaximumpressuresuggestedbythetire
manufactureronthesidewallofthecasterwheeltires.
Formachineswith42-inchor50-inchdecks,inatetherear
drivewheeltiresto90kPa(13psi).
Formachineswith60-inchdecks,inatethefrontcastersand
reardrivewheeltiresto103kPa(15psi).
g000554
Figure48
1.Valvestem
40