Operator's Manual

ServicingtheFuses
Theelectricalsystemisprotectedbyfuses.Itrequires
nomaintenance;however,ifafuseblows,checkthe
componentorcircuitforamalfunctionorshort.
Fusetype:
Main—F1-30A,blade-type
ChargeCircuit—F2-25A,blade-type
1.Removethescrewssecuringthecontrolpanel
tothemachine.
Note:Retainallfasteners.
2.Liftthecontrolpaneuptoaccessthemainwiring
harnessandfuseblock(Figure40).
3.T oreplaceafuse,pulloutthefusetoremove
it(Figure40).
g014921
Figure40
1.Main—30A
2.Chargecircuit—25A
4.Returnthecontrolpaneltoitsoriginalposition.
Note:Usethescrewsremovedpreviouslyto
securethepaneltothemachine.
DriveSystem
Maintenance
CheckingtheTirePressure
ServiceInterval:Every25hours—Checkthetire
pressure.
Maintaintheairpressureinthefrontandreartiresas
specied.Uneventirepressurecancauseuneven
cut.Checkthepressureatthevalvestem(Figure41).
Checkthetireswhentheyarecoldtogetthemost
accuratepressurereading.
Refertothemaximumpressuresuggestedbythetire
manufactureronthesidewallofthecasterwheeltires.
Inatethereardrivewheeltiresto90kPa(13psi).
g000554
Figure41
1.Valvestem
40