Operator's Manual

11.Adjustthepump-control-rodlengthsbyrotating
thenutintheappropriatedirectionuntilthe
wheelsslightlycreepinreverse(Figure80).
g036753
Figure80
1.Nut4.Return-to-neutralplate
2.Stationaryplate
5.Tabstouchingreturnto
neutralplate
3.Controlplate
12.Movethemotion-controlleverstotheREVERSE
positionandwhileapplyingslightpressureto
thelever,allowthereverse-indicatorspringsto
bringtheleversbacktoneutral.
Note:Thewheelsshouldstopturningorslightly
creepinreverse.
Note:Youmayneedtoremovethe
motion-controlcovertogainaccess.
13.Shutoffthemachine.
14.Removethejumperwirefromthewireharness
andplugtheconnectorintotheseatswitch.
15.Removethejackstands.
16.Raisethemowerdeckandinstallthe
height-of-cutpin.
17.Checkandensurethatthemachinedoes
notcreepinneutralwiththeparkingbrake
disengaged.
HydraulicSystem
Maintenance
HydraulicSystemSafety
Seekimmediatemedicalattentionifuidisinjected
intoskin.Injecteduidmustbesurgicallyremoved
withinafewhoursbyadoctor.
Ensurethatallhydraulic-uidhosesandlinesare
ingoodconditionandallhydraulicconnections
andttingsaretightbeforeapplyingpressureto
thehydraulicsystem.
Keepyourbodyandhandsawayfrompinhole
leaksornozzlesthatejecthigh-pressurehydraulic
uid.
Usecardboardorpapertondhydraulicleaks.
Safelyrelieveallpressureinthehydraulicsystem
beforeperforminganyworkonthehydraulic
system.
HydraulicFluid
Specications
HydraulicFluidType:T oro
®
HYPR-OIL
500
hydraulicuidorMobil115W-50oil.
Important:Usethespecieduid.Otheruids
coulddamagethehydraulicsystem.
HydraulicSystemCapacity(withltersremoved):
4.45L(150oz)
CheckingtheHydraulic
FluidLevel
ServiceInterval:Beforeeachuseordaily
1.Allowthehydraulicuidtocooldown.Checkthe
oillevelwhentheuidiscold.
2.Checkexpansionreservoirandifnecessary
addToro
®
HYPR-OIL
500hydraulicuidtothe
FULLCOLDline.
60