Service Manual

3-9
Digital Edition - TITAN® HD Service Manual
January 2018
Table of Contents
MAINTENANCE
Maintenance
Servicing the Toro V-Twin Engine
Servicing the Air Cleaner
Service Interval Maintenance Procedure
Daily or before starting engine • Check for build-up of dirt and debris around the air cleaner system
• Check for loose or damaged components, replace or make appropriate
repairs
• Replace all bent or damaged air cleaner components
Every 25 hours/monthly
(whichever comes rst)
• Clean the air cleaner foam element*
Every 100 hours/yearly
(whichever comes rst)
• Service the air cleaner paper element*
• Replace the air cleaner foam element*
Every 200 hours/every 2 years
(whichever comes rst)
• Replace the air cleaner paper element*
*More often in dusty/dirty conditions
NOTE: Operating the engine with loose or damaged air cleaner components could allow unltered air into
the engine causing premature wear and failure.
NOTE: Service the air cleaner more often under extremely dusty, dirty conditions.
Removing the Elements
1. Park the machine on a level surface, disengage the PTO, move the motion control levers to the brake position,
stop the engine, remove the key and wait for all moving parts to stop before leaving the operating position.
2. Clean around the air cleaner cover to prevent dirt from getting into the engine and causing damage.