Operator's Manual

Setup
MountingtheBattery
Charger(Optional)
Ifdesired,mountthebatterychargersecurelyona
wallusingthewall-mountkeyholesonthebackof
thecharger.
Mountitindoors(suchasagarageorotherdryplace),
nearapoweroutlet,andoutofthereachofchildren.
RefertoFigure1forassistanceinmountingthe
charger.
Note:Slideandtwistthechargeroverthe
appropriatelypositionedhardwaretosecurethe
chargerinplace(hardwarenotincluded).
g194202
Figure1
ProductOverview
Specications
BatteryCharger
Model88542
Type40VMAXLithium-IonBattery
Charger
Input
100to120VAC50/60HzMax
3.0A
Output41.8VMAXDC2.5A
BatteryPack
Model8854088541
Voltagepercell3.6V3.6V
Numberofcells
1020
Batterypack
voltage
36V36V
Batterypack
capacity
2.5Ah5.0Ah
Batterymanufacturerrating=40Vmaximumand36Vnominal.
Actualvoltagevarieswithload.
AppropriateTemperatureRanges
Chargethebatteryat0°C(32°F)to40°C(104°F)*
Useproductsat
-15°C(5°F)to60°C(140°F)
Storeproductsat-15°C(-5°F)to60°C(140°F)
UnplugthechargerifBelow0°C(32°F)orabove
40°C(104°F)
*Chargingtimewillincreaseifyoudonotchargethe
batterywithinthisrange.
Storethetool,batterypack,andbatterychargerinan
enclosedclean,dryarea.
5