Performance Charts

ACCESSORIES
Tape Fittings, 5/8" Ring-Loc
Part Number Carton Qty. Description
FCC98 100/1,000 Coupling
FCR 1098 100/1,200 Reducer Coupling, 10 mil x tape
FCR1398 100/1,200 Reducer Coupling, 13 mil x tape
FCR1698 100/1,200 Reducer Coupling, 16 mil x tape
FEE98 100/700 Elbow, tape x tape
FTT98 100/500 Tee, tape x tape
FTS98 100/400 Swivel Tee (3/4" FHT)
FJJ98 100/500 Hose End (3/4" hose thread)
w/out cap
FJA98 100/800 Hose End (3/4" hose thread)
w/ cap
FAM98 100/1,000 Male Adapter (1/2" NPT)
FAS98 100/700 Hose Swivel (3/4" FHT)
FCA 0598 100/2,500 5mm or 6mm tubing barb fittings
FCA 0798 100/2,500 7mm barb x Tape Loc-Eze
FEP3198 N/A Replacement Ringlock
for Tape fittings
Tape Fittings, 7/8" Lock Sleeve
Part Number Carton Qty. Description
FCC78 250 7/8" Coupling
FCA1678 250 7/8" Adapter x 16 mm Barb
FLA78 250 7/8" Adapter x layflat
FCS78 250 7/8" Adapter x 3/4" Slip
HCA78 250 7/8" Adapter x OD Compression
FJJ78 250 7/8" Threaded end cap
Shipping Quantities (16 rolls/pallet)
20 ft 24 ft 40 ft 40 ft 53 ft
Container High Cube LTL Container High Cube Trailer
# of reels 240 336 362 480 560 724
SPECIFICATIONS
5/8" Diameter Tape
Wall Thickness 4 mil 6 mil 8 mil 10 mil 12 mil 15 mil
Reel Length 13,000 ft. 10,000 ft. 7,500 ft. 6,000 ft. 5,100 ft. 4,500 ft.
Reel Weight 70 lbs. 66 lbs. 62 lbs. 59 lbs. 58 lbs. 61 lbs.
Reel Diameter 21" 21" 21" 21" 21" 21"
Reel Height 11" 11" 11" 11" 11" 11"
Reel Through-
Hole Diameter 1" 1" 1" 1" 1" 1"
Operating
Pressure 4–10 psi 4–12 psi 4–15 psi 4–15 psi 4–15 psi 4–15 psi
7/8" Diameter Tape
Wall Thickness 8 mil 10 mil 12 mil 15 mil
Reel Length 6,000 ft. 4,400 ft. 4,000 ft. 3,000 ft.
Reel Weight 68 lbs. 65 lbs. 61 lbs. 62 lbs.
Reel Diameter 21" 21" 21" 21"
Reel Height 11" 11" 11" 11"
Reel Through-
Hole Diameter 1" 1” 1" 1"
Operating Pressure 4–15 psi 4–15 psi 4–15 psi 4–15 psi
*note: Can flow has a reel through-hole of 1
1
/
2
" diameter.
1
3/8
" Diameter Tape
Wall Thickness 15 mil
Reel Length 2700 ft.
Reel Weight 74 lb.
Reel Diameter 21"
Reel Height 11"
Reel Through-hole Diameter 1"
Operating Pressure 4-15 psi
Specifications and Dimensions
Number of Inlets 8" & 16" spacing 60
Number of Inlets 12" & 24" spacing 200
Inlet Openings (All) .007 min. x .010 max.
Flowpath Dimensions (All) .010 min. x .033 max.
Outlet Dimensions 4 & 6 mil .160 x .012
Outlet Dimensions 8, 10 & 12 mil .190 x .012
Coefficient of Variation (All) <0.03
Flow Exponent High & Medium Flow (6 - 12 psi range) 0.50
Flow Exponent Low Flow (6 - 12 psi range) 0.54
Hazen-Williams C Factor (Main Tube) 140
Aqua-Traxx
®