Design Guide

Installation
_____________________________________________________________Landscape Dripline Design
Recommended Installation Instructions
DZK-EZF-075-LF
DZK-EZF-075-MF
Detail No.1
Detail No.2
23
1. CONTROL WIRES WITH 12” SERVICE
COIL AND WATER PROOF WIRE
CONNECTIONS, DBY OR EQUAL.
2. TORO EZF-29-03 ANTI-SIPHON VALVE (*).
3. TORO 150 MESH Y-FILTER (*).
4. TORO 25 PSI MEDIUM FLOW PRESSURE
REGULATOR (*).
5. SCH 80 PVC CLOSE NIPPLE (*).
6. SCH 40 PVC BALL VALVE (*).
7. SCH 40 PVC MALE ADAPTER.
8. CONTROL WIRES TO CONTROLLER.
9. PVC MAINLINE PER SPECIFICATIONS.
10. PVC MAINLINE FITTING.
11. NATIVE SOIL PER SPECIFICIATIONS.
12. PVC LATERAL LINE PER SPECIFICATIONS.
13. FINISH GRADE.
14. PVC SCH 40 ELBOW (SxS).
15. LATERAL LINE TO DRIP SYSTEM.
16. HEIGHT ABOVE GRADE PER LOCAL
CODES (8” MINIMUM).
(*) PARTS IN DRIP ZONE KIT.
1. FINISH GRADE.
2. CONTROL WIRES WITH 36” SERVICE COIL
AND WATERPROOF WIRE CONNECTIONS,
DBY OR EQUAL.
3. RECTANGULAR PLASTIC VALVE BOX. HEAT
BRAND STATION NUMBER ON LID IN 2”
HIGH CHARACTERS.
4. PVC MAINLINE PER SPECIFICATIONS
(LENGTH AS REQUIRED).
5. SCH 40 PVC ELBOW (SxS).
6. NATIVE SOIL PER SPECIFICATIONS.
7. CONTROL WIRES TO CONTROLLER.
8. PVC MAINLINE FITTING.
9. TORO EZF-26-04 INLINE VALVE.(*)
10. TORO 150 MESH Y-FILTER.(*)
11. TORO 25 PSI LOW-FLOW PRESSURE
REGULATOR.(*)
12. SCH 40 PVC MALE ADAPTER.
13. SCH 40 PVC BALL VALVE.(*)
14. SCH 80 PVC CLOSE NIPPLE.(*)
15. PEA GRAVEL SUMP, MINIMUM 6” DEEP.
16. BRICK SUPPORTS (4 COMMON BRICKS
REQUIRED).
17. LATERAL LINE TO DRIP SYSTEM.
*PARTS IN DRIP ZONE KIT