Installation Manual
6
5.  e controller will detect the soil sensor. Conrm that the 
sensor ID detected matches the sensor’s SN ID.
6.  If it does match, press   and continue to Calibrate the 
Sensor. 
If it does not match, change YES to NO, press  , and 
repeat steps 3-5.
2.  Install and Calibrate the Sensor
e Precision™ Soil Sensor interprets soil moisture content on 
a scale of 0% (extremely dry) to 100% (very wet). e key to 
understanding how to calibrate a soil sensor is that the operator 
must teach the 100% moisture level to the sensor.
1.  After selecting YES from the previous screen, follow the 
onscreen instructions below. Install the soil sensor in the 
ground. 
(See Appendix B: Site Selection and Earth Installation for 
complete instructions on good sensor location.) 
 If soil sensor is not installed in the ground within that 30 
minute “window”, the controller removes the sensor and 
installation will have to be redone.
2.  Return to the controller and conrm that the signal 
strength (see above graphic) is good. If signal strength is 
weak, relocate the sensor to a spot closer to the controller.
3.  Press   when satised.Use the   and   to adjust 
the calibration setting (default 5: approximately a 1-day 
“watch window”). Press  .
  e “Cal Setting” number adjusts the time it takes to 
calibrate the sensor. A Cal Setting of ‘0’ calibrates the 
sensor to the current moisture level in the ground. e 
SOIL 1
DEVICE ID   05952
CORRECT? 
ADD/REMOVE DEVICE
YES
INSTALL SENSOR
IN GROUND
SIGNAL STRENGTH
ADD/REMOVE DEVICE
CONTINUE