User's Manual

20
Sensors
e Sensors function allows you to assign a rain sensor to each of the schedules. Schedules with a rain sensor assigned will not water when
the sensor is activated.
Step 1 While in the ADVANCED menu, use the Up
or Down arrows to select the SENSORS. Press SELECT .
Step 2 Use the Up
or Down arrows to select the sensor you want to set.
Step 3 Use the Left
or Right arrows to select the schedule.
Step 4 Use the Up
or Down arrows to place a check mark under the desired schedules to assign the rain sensor. When the
rain sensor is activated, EVOLUTION
TM
will prevent schedules from operating. Replace the check mark with a dash to disable
the sensor for that schedule.
SENSORS
A B Ca
RAIN
Use the Right arrows to select to access the sensor setup screen.
RAIN SENSOR
RAIN DELAY OFF
CURRENT STATE IS DRY
Step 5 Select Rain Delay. Press SELECT or Right arrows to navigate to the parameter.
Step 6 Use the Up
or Down arrows to set a delay of 1-14 days or OFF. e rain delay is the waiting period after the rain
sensor is detected to be dry.
Step 7 Press the BACK
arrow to return to the previous menu or HOME to return to the main screen.
Diagnostics
e EVOLUTION
TM
controller provides a diagnostic function to check whether the systems zones are properly functioning. When
activated, the controller will test each available zone. EVOLUTION
TM
will display dashes (--) for zones that are being tested and have not
been tested, OK for zones working within the current draw range, OVERCRNT for zones drawing above the recommended current draw,
or SHORT for zones that have a grounded circuitry.
DIAGNOSTICS
ZONE TEST
ZONE CURRENT TEST
MASTER VALVE OK
ZONE 1 OVERCRNT
ZONE 2 SHORT
ZONE 3 ––