User manual

Groundsmaster 4000--D/4010--D Hydraulic SystemPage 4 -- 101
Removal (Fig. 76)
1. Read the General Precautions for Removing and
Installing Hydraulic System Components at the begin-
ning of the Service and Repairs section of this chapter.
2. Topreventcontaminationofhydraulicsystemduring
manifold removal, thoroughly clean exterior of manifold
and fittings.
3. Disconnect wire harness connector from the sole-
noid valve coil on the traction manifold.
4. Disconnect hydraulic lines from manifold and put
capsorplugsonopenhydraulic linesand fittings.Label
disconnected hydraulic lines for proper reassembly.
5. Remove traction manifold from the frame using Fig-
ure 76 as a guide.
6. Ifhydraulic fittings are to be removed from manifold,
mark fitting orientation to allow correct assembly. Re-
move fittings from manifold and discard O--r ings.
Installation (Fig. 76)
1. Iffittings were removed from manifold, lubricate and
place new O--rings onto fittings. Install fittings into man-
ifold openings using marks made during the removal
process to properly orientate fittings. Tighten fittings
(see Hydraulic Fitting Installation in the General Infor-
mation section of this chapter).
2. Installtraction manifold to the frame using Figure 76
as a guide.
3. Removecapsandplugsfromfittingsandhoses.Us-
inglabelsplacedduringmanifoldremoval,properlycon-
necthydrauliclinestomanifold(seeHydraulicHoseand
Tube Installation in the General Information section of
this chapter).
4. Connect wire harness connector to the solenoid
valve coil on the traction manifold.
5. Makesurehydraulictankisfull.Addcorrectoilifnec-
essary before returning machine to service.
Hydraulic
System