Sell Sheet

FLEX800
35/55 SERIES GOLF ROTORS
www.toro.com / e Toro Company, Irrigation Division / 5825 Jasmine Street, Riverside, CA 92504 / 877-345-8676 / Specications subject to change without notice / © 2015. All rights reserved / P/N 15-5059-IG
FLX35 Conversion Upgrades
Models Description
• FLX35-3134
• FLX35-3537
• FLX35-3134E
• FLX35-3537E
FLX35 w/31–34 Nozzles
(#3 Nozzle Installed)
FLX35 w/35–37 Nozzles
(#5 Nozzle Installed)
FLX35 w/31–34 Nozzles
(#3 Nozzle Installed), Effluent
FLX35 w/35–37 Nozzles
(#5 Nozzle Installed), Effluent
FLX55 Conversion Upgrades (Ribbed Body)
Models Description
• FLX55-5154
• FLX55-5558
• FLX55-59
• FLX55-5154E
• FLX55-5558E
• FLX55-59E
• 102-5011
FLX55 w/51–54 Nozzles
(#3 Nozzle Installed)
FLX55 w/55–58 Nozzles
(#5 Nozzle Installed)
FLX55 w/59 Nozzle
FLX55 w/51–54 Nozzles
(#3 Nozzle Installed), Effluent
FLX55 w/55–58 Nozzles
(#5 Nozzle Installed), Effluent
FLX55 w/59 Nozzle, Effluent
690 Adapter
allows you to upgrade
any 690 with FLX55
conversions
FLX55 Conversion Upgrades (Ribless Body)
Models Description
• FLX55-5154R
• FLX55-5558R
• FLX55-59R
• FLX55-5154RE
• FLX55-5558RE
• FLX55-59RE
FLX55 w/51–54 Nozzles
(#3 Nozzle Installed)
FLX55 w/55–58 Nozzles
(#5 Nozzle Installed)
FLX55 w/59 Nozzle
FLX55 w/51–54 Nozzles
(#3 Nozzle Installed), Effluent
FLX55 w/55–58 Nozzles
(#5 Nozzle Installed), Effluent
FLX55 w/59 Nozzle, Effluent
Specifying Information—FLX35 & FLX55
FLXX5-XXX-X-7
Body
Inlet
Arc Nozzle
Pressure
Regulation*
Activation Type Optional
FLXX 5 X X X X 7
3—1"
5—1
1
2"
5—Part-circle and
Full-circle
In One
FLX3530, 31, 32, 33 , 34, 35, 36, 37
FLX5551, 52, 53, 54, 55, 56, 57, 58, 59
6—65 PSI
8—80 PSI
1—100 PSI
1—Standard Solenoid
2—Spike Guard
Solenoid
3—Nickel-plated Spike Guard Solenoid
4—DC Latching Solenoid (DCLS)
5—Integrated GDC Module w/DCLS
7—Effluent
Example: When specifying an FLX35 Series Sprinkler with #34 nozzle, pressure regulation at 65 PSI and Spike Guard you would specify: FLX35–346–2
Note: Not all models available. * All sprinklers are equipped with the selectable pilot valve that allows settings at 50, 65, 80 and 100 PSI.
Dimensions
Body Flange Diameter:
- FLX35-6: 6
1
/2
- FLX55-6: 7
1
/2
• Body height:
- FLX35: 10”
- FLX55: 11
3
/8
• Weight:
- FLX35-6: 2.89 lbs.
- FLX55-6: 3.57 lbs.
• Weight–Integrated GDC
- FLX35: 3.58 lbs.
- FLX55: 4.26 lbs.
Pop-up height to nozzle: 3¼”
Additional Features
• FLX35 has eight nozzle
variations (30, 31, 32, 33,
34, 35, 36 & 37)
FLX55 has nine nozzle
variations (51, 52, 53, 54,
55, 56, 57, 58 & 59)
Three in-line nozzles,
rotating stream pattern
Two back nozzle positions
Stator variations: 3
Radius reduction screw
363-4839 for fine tuning
Ratcheting riser
Nozzle base clutching
Warranty
• Three years
• Five years when installed with Toro Swing Joints
Operating Specifications
• Inlet:
- FLX35: 1” ACME
- FLX55: 1½” ACME
• Radius:
- FLX35: 43’ – 83’
- FLX55: 55’ – 92’
• Flow Rate:
- FLX35: 8.2 – 47.3 GPM
- FLX55: 14.1 – 61.3 GPM
• Precipitation Rates:
- FLX35: Minimum - .41”/hr; Maximum - .45”/hr
- FLX55: Minimum - .46”/hr; Maximum - .58”/hr
• Pilot Valve: Selectable at 50, 65, 80 and 100 PSI
• Recommended Operating Pressure Range: 65-100 PSI
(maximum – 150 PSI and minimum – 40 PSI)
• Activation types – Electric Valve-in-Head:
- Standard Solenoid:
n
24 VAC, 50/60 Hz
n
Inrush: 0.30 A
n
Holding 0.20 A
- Spike Guard Solenoid:
n
24 VAC, 50/60 Hz
n
Inrush: 0.12 A
n
Holding 0.10 A
- Nickel-Plated Spike Guard Solenoid:
n
24 VAC, 50/60 Hz
n
Inrush: 0.12 A
n
Holding 0.10 A
- DC Latching Solenoid (DCLS):
n
Momentary low voltage pulse
- Integrated GDC Module w/DCLS:
n
Momentary low voltage pulse