user manual

Groundsmaster 4100--D Page 5 -- 11 Electrical System
Component Testing
For accurate resistance and/or continuity checks, elec-
tricallydisconnect thecomponentbeing testedfrom the
circuit (e.g. unplug the ignition switch connector before
doing a continuity check).
NOTE: For engine component testing information,see
the Kubota Workshop Manual, Diesel Engine,
V2403--M--T--E3B Series at the end of Chapter 3 -- Ku-
bota Diesel Engine.
CAUTION
Whentesting electrical componentsfor continu-
ity with a multimeter (ohms setting), make sure
that power to the circuit has been disconnected.
Ignition Switch
The ignition (key) switch has three positions: OFF, ON/
PREHEAT and START (Fig. 11). The terminals are
marked as shown in Figure 12. The circuit wiring of the
ignition switch is shown in the chart. With the use of a
multimeter (ohms setting), the switch functions may be
tested to determine whether continuity exists between
thevariousterminals for eachposition. Verify continuity
between switch terminals.
POSITION
CIRCUIT
OFF NONE
ON / PREHEAT B+I+A, X+Y
START B+I+S
Figure 11
45
°
ON / PREHEAT
START
OFF
45
°
Figure 12
A
B
S
Y
X
I
Electrical