Groundsmaster 4100--D Page 5 -- 23 Electrical System
TEC--5002 Controller
Groundsmaster4100--Dmachines useaToroElectron-
ic Controller (TEC) to control the operation of the hy-
draulic cooling fan. The controller is attached to the
operatorplatformundertheconsolehousingcover(Fig.
34).
Logic power is provided to the controller as long as the
battery cables are connected to the battery. A 2 amp
fuse in a fuse holder near the battery provides circuit
protection for this logic power to the controller.
The TEC--5002 controller monitors the states of the fol-
lowing components as inputs: ignition switch, hydraulic
temperature sender, engine coolant temperature send-
er and cooling fan switch.
The TEC--5002 controller controls electrical output to
the engine cooling fan hydraulic valve solenoid coils
(speed and direction). Circuit protection for TEC--5002
outputs is provided by fuse F9 (7.5 amp).
Because of the solid state circuitry built into the TEC,
thereisnomethodtotestthecontrollerdirectly.Thecon-
troller may be damaged if an attempt is made to test it
with an electrical test device (e.g. digital multimeter or
test light).