Specifications

The central control shall offer a Pump Integration software option shall support up to 99 alarm responses.
The central controller shall provide system status information on communication with the Gate Way(s) and
wire paths automatically and continuously without requiring alarm configuration.
The central controller shall provide reports detailing the following information: 1) projected schedule activity,
2) contents of the database constructed while programming the central controller, 3) overview of scheduled irrigation
activity including start time, end time and area information, flow and program, 4) report stations that did not
acknowledge a message to run.
The central controller shall be capable of monitoring 1 pump stations manufactured either Flowtronex,
Watertronics or Grundfos. The central controller shall be capable of displaying flow and pressure.
With the Optional Pump Integration software, the central controller shall be capable of responding to “alarm”
conditions based on data received from the Flowtronex, Grundfos or Watertronics pump station. When alarms are
activated, the irrigation system will respond in one of the following ways: log only no response, pause irrigation, resume
irrigation, turn a switch on/off, cancel a program or station, initiate a rain hold or cancel, start a program or initiate a Re-
Flow response. The central controller shall have “Power Guard”, the ability to limit electrical consumption during
specified times when integrated with a Flowtronex Pump station equipped with their Pace controls.
The system shall require a personal computer which has been certified by the manufacturer for use with the
central control system.
The system shall come with a one-year dedicated support program provided by the manufacturer which
includes extended warranties, 24-hour component replacement, toll-free help-line support and remote diagnostics by a
licensed irrigator.
The system shall include NSN Connect for secure remote access to allow the user to operate the Lynx system
from any computer connected to the internet. This will also allow NSN to do remote diagnostics and support of the
central controller.
The system shall include one year of NSN Connect Plus, a service that will allow NSN to remotely monitor the
computer 24/7/365 and will alert the user to internal computer hardware and software issues.
The system shall include one year of Lynx Mobile, a service which will allow the user to remotely control Lynx
24/7/365 from any web enabled mobile device. This service will provide for manual irrigation, communication
diagnostics, viewing of course status and alerts
The central controller shall be developed, manufactured, qualified and released in the USA by an ISO 9001-
certified facility. The central controller, model number ____________, shall be manufactured by The Toro Company,
Irrigation Division, Riverside, California, USA.
Note: Lynx, Electro-Flow, NSN, NSN Connect and NSN Connect Plus are trademarks of The Toro Company.
Microsoft and Windows are registered trademarks of Microsoft, Inc.