User's Manual
6
The Advanced System Operations Menu lists a variety of operational set-
tings and system status indicators. For most residential landscape appli-
cations, the default settings will provide good results. Each setting has a
range of adjustment enabling its function to be tailored as preferred.
•
Press and release the Menu button to step through the menu
sequence shown in the table below.
Note: If you step past a specic menu item, continue pressing the Menu
button to repeat the menu sequence.
PrecisionSystemMenuItem DefaultSetting Range
System Calibration Mode Automatic Manual Reset
Watering Completion Time 4 Hours 0–24 Hours
Smart Bypass Timer 24 Hours 1–199 Hours
Freeze Shut-o Mode Temp 39°F 35–45°F (2–7°C)
Signal Strength Indicator Review Only 0.0–10.0+
Battery Voltage Indicator Review Only 0.0–4.5+
Sensor Identication Code Review Only 00 00 00–99 99 99
Temperature Format Indicator °F °F or °C
Sensor Temperature
Review Only
14° F –140° F+
•
Where applicable, press the Plus or Minus buttons to adjust the
setting value.
• ToexittheAdvancedSystemOperationsMenu,eitherpresstheMenu
button to display the Operating Mode screen, or allow the receiver
to idle for 10 seconds and exit automatically.
SystemCalibrationMode
Enables the sensor system to be manually calibrated for
current maximum soil moisture content.
WateringCompletionTime(0–24Hours)
Determines the amount of time allowed for a watering
cycle to be completed before the Watering Restricted
mode takes eect.
SmartBypassTimer(1–199Hours)
Determines the amount of time the system remains in
Smart Bypass mode (and after Freeze Shut-o mode)
before returning to the Normal Operating mode.
FreezeShut-oModeTemp(35–45°For2–7°C)
Determines the temperature that initiates the Freeze
Shut-o mode to suspend watering operation.
SignalStrength
Indicates signal strength in a digital format.
BatteryVoltage
Indicates total voltage output of the sensor batteries.
SensorIDCode
The Sensor Identication Code is displayed in three
number pairs, accessed by repeatedly pressing the
Plus or Minus button.
TemperatureFormat
Enables temperature format to be displayed in degrees
Fahrenheit or Centigrade.
Sensor Temperature
Indicates the sensor temperature.
AdvancedSystemOperationsMenu