The Advanced System Operations Menu lists a variety of operational set-
tings and system status indicators. For most residential landscape appli-
cations, the default settings will provide good results. Each setting has a
range of adjustment enabling its function to be tailored as preferred.
Press and release the Menu button to step through the menu
sequence shown in the table below.
Note: If you step past a specic menu item, continue pressing the Menu
button to repeat the menu sequence.
PrecisionSystemMenuItem DefaultSetting Range
System Calibration Mode Automatic Manual Reset
Watering Completion Time 4 Hours 0–24 Hours
Smart Bypass Timer 24 Hours 1–199 Hours
Freeze Shut-o Mode Temp 39°F 35–45°F (2–7°C)
Signal Strength Indicator Review Only 0.0–10.0+
Battery Voltage Indicator Review Only 0.0–4.5+
Sensor Identication Code Review Only 00 00 00–99 99 99
Temperature Format Indicator °F °F or °C
Sensor Temperature
Review Only
14° F –140° F+
•
Where applicable, press the Plus or Minus buttons to adjust the
setting value.
• ToexittheAdvancedSystemOperationsMenu,eitherpresstheMenu
button to display the Operating Mode screen, or allow the receiver
to idle for 10 seconds and exit automatically.
SystemCalibrationMode
Enables the sensor system to be manually calibrated for
current maximum soil moisture content.
WateringCompletionTime(0–24Hours)
Determines the amount of time allowed for a watering
cycle to be completed before the Watering Restricted
mode takes eect.
SmartBypassTimer(1–199Hours)
Determines the amount of time the system remains in
Smart Bypass mode (and after Freeze Shut-o mode)
before returning to the Normal Operating mode.
FreezeShut-oModeTemp(35–45°For2–7°C)
Determines the temperature that initiates the Freeze
Shut-o mode to suspend watering operation.
SignalStrength
Indicates signal strength in a digital format.
BatteryVoltage
Indicates total voltage output of the sensor batteries.
SensorIDCode
The Sensor Identication Code is displayed in three
number pairs, accessed by repeatedly pressing the
Plus or Minus button.
TemperatureFormat
Enables temperature format to be displayed in degrees
Fahrenheit or Centigrade.
Sensor Temperature
Indicates the sensor temperature.
AdvancedSystemOperationsMenu