Owner's Manual

Program Data Menu
Start Times:
The controller offers eight start times per program. If more than eight start times are needed, see
Repeats and Continuous Run below. Use this menu item to display/edit any one of the eight start times. Use the
CLUSTER SELECT and the PROGRAM SELECT keys to select the desired cluster program. Use the Up and Down
arrow keys to position the cursor under the field being edited and edit as desired. Use the Up and Down arrow keys to
select the start time being edited and toggle to the A (AM) or P (PM). To eliminate a start time, press the OFF key.
Press ENTER to save the data.
Slt Stn Time: Select this menu item to assign a station to a slot and enter the run times for the slot/stations. From the
factory, the slot and station numbers are set to be the same; i.e., Station 1 is assigned to Slot 1 and will run first.
Station 2 will run next in Slot 2, etc. Use the CLUSTER/SCHEDULE SELECT and the PROGRAM SELECT keys to
select the desired cluster program. Use the Right and Left arrow keys to position the cursor under the slot field. Use
the Up and Down arrow keys to select the slot desired. Press the Right arrow key to select the desired stations to run
in the slot shown. Press the Right arrow again to position the cursor under the time field. Enter the desired run time
and press ENTER to save.
Note: This feature allows the user to run any station in any order (slot) desired and even repeat the desired station
within the same program. Keep in mind that the controller will run the slots sequentially. Stations can be assigned to
slots allowing any order of programming.
Percent Scale: This menu item allows you to scale all the slot/station run times in a program Up or Down by
percentage. Use the CLUSTER SELECT and the PROGRAM SELECT keys to select the desired cluster program.
Position the cursor under the field being edited and edit as desired. Press ENTER to save.
Repeats: Repeats can be used to do cycle & soak or to increase a programs cycle more than the eight start times.
Use the CLUSTER SELECT and the PROGRAM SELECT keys to select the desired cluster program. Position the
cursor under the Repeat field and edit as desired. Press ENTER to save.
Repeat Dly Time: Repeat delay time is the amount of time that lapses before a program will repeat. Use this menu
item to display/edit the repeat delay time for any one of the 16 programs. Use the CLUSTER SELECT and the
PROGRAM SELECT to select the desired cluster program. Position the cursor under the field to be edited and edit as
desired. This is used in conjunction with Repeats above. Press ENTER to save.
Continuous Run: The controller is capable of running any one or combination of programs continuously. To manually
start the desired cluster program, use the same procedure as in Auto Slot/Stn (refer to page 2). Use the CLUSTER
SELECT and the PROGRAM SELECT keys to select the desired cluster program. Use the ON and OFF keys to turn
continuous run on and off. Press ENTER to save. Use Water Windows below to set up continuous run start and stops
automatically.
Water Windows: A water window may be entered where watering will only take place between the two set times. Use
the CLUSTER SELECT and the PROGRAM SELECT keys to select the desired cluster program. Position the cursor
under FROM or TO and toggle using the Up and Down arrow keys. Use the Right and Left arrow keys to position the
cursor under the time digit to be edited and edit as desired. Use the Right arrow key to place the cursor under the
A (AM) or P (PM) field. Press ENTER to save. Pressing the OFF key will clear the water window entry. Press ENTER
after any change to save.
Assigned Schedule: Selecting this menu item allows you to assign any of the four schedules to any of the
16 programs. Use the CLUSTER SELECT and the PROGRAM SELECT keys to select the desired cluster program.
Use the Right and Left arrow keys to position the cursor under the field to be edited and edit as desired. Use the Up
and Down arrow keys to select from schedule 1 4. Press ENTER after any change to save.
5