Owner's Manual

Command Operation
CCC 00 h tt If running a sequence of stations, use this command to set the
run time duration. As an example, sending 555 00 1 30 command
instructs satellite unit 555 to run a sequence for 1 hour and 30 minutes.
CCC nn # Send this command to start irrigation for all station in sequence,
where CCC is the satellite unit and nn is the first station to irrigate
in sequence.
CCC 3 # Sending this command will step from the currently operating station to
the next higher station number. As an example, if station 16 of unit 555
is currently in operation and the 555 3 # command is transmitted,
station 16 will stop and station 17 will initiate operation.
CCC 1 # Sending this command will step from the currently operating station to
the next lower station number.As an example, if station 16 of unit 555 is
currently in operation and the 555 1 # command is transmitted,
station 16 will stop and station 15 will initiate operation.
CCC 00 # Sending 555 00 # will stop satellite unit 555’s sequence operation.
Command Operation
CCC #Cp# This command instructs the satellite unit CCC to start the specified
cluster program. The C designates the cluster number, 1 for cluster A, 2
for cluster B, etc. The p designates the program number within the
specified cluster. As an example, if command 555 #24# is transmitted,
cluster B program 4 of unit 555 will start.
CCC #C3* This command instructs the satellite unit CCC to stop the specified
cluster in operation. The C designates the cluster number (1 for cluster
A, 2 for cluster B, etc.) to stop operation.
Semi Auto Program Commands Under Secure Mode
Sequence Related Commands Under Secure Mode
A- 38
Toro Sentinel Central Software Users Guide
Action
Set sequence time.
Start sequence operation.
Increment sequence.
Decrement Sequence
Stop sequence operation.
Action
Start cluster program.
Stop cluster program.