System Guide

Placing Station Indicators on the Map
When station indicators are positioned on the map image, they are
dynamically linked to the Sentinel WMS software to reflect current operating
conditions. For example, during manual operations, the station indicator will
change from blue (inactive) to yellow (manual operation). During automatic
operation, active stations will be displayed in green.
1. Use either of the following methods to place station indicators on the map
image:
• By Numeric Sequence:
Click and drag an indicator from the blue stack in the upper left corner of
the map image, then drop the indicator at the corresponding map location.
Station indicators are extracted from the stack in numeric sequence,
from 1 to 96.
To remove an indicator from the map, simply drag it back to the corner
stack, then release.
• By Random Sequence:
Choose Shadow View from Map Options menu to open the Shadow
window.
Click and drag an indicator from the
Shadow window, then drop the indicator
at the corresponding map location.
To remove a station number for the map
image, click on the corresponding
number in the Shadow window.
To automatically locate a station
number on the map that is currently
hidden from vie
w
,
right-c
lic
k
on the
number in the Shadow window.
Part 2 – Manual Operations/Output Status
The options provided in the Manual/Output Status enable individual satellite
stations to be started and stopped as needed. A temporary station run time is
assigned for manual operation, ranging from 1 to 255 minutes.
Manual Operations
1. To begin, choose Manual/Output Status window from the Operations &
Status directory.
Note: A Receive Flow button enables an immediate sampling and retrieval
of the flow rate (requires firmware versions 1.42/2.42 and above)
.2. Choose Receive to download current data from the satellite.
Note: Reference the color key to determine manual, automatic and
auxiliary pump operations indicated on station status fields.
3. Select the station number to operate manually. An orange highlight will
appear on the number to indicate manual operation.
4. The run time of the manual operation is determined by the minutes setting
in the Time to run new manuals selection field. Select a run time from
1–255 minutes using the Up/Down arrow buttons or keyboard.
5. To activate a Master output, select the Master check box.
6. Choose Send to initiate the manual start. The stations will run for the
selected duration. To turn off a station at any time, simply click on the
station number and choose
Send.
Note: Ho
ver the mouse pointer over the active station number to review
the current status
.
Inf
or
mation regarding prog
ram assignment and
remaining run time will be displayed.
Note: The cum
ulativ
e
Expected Flo
w
f
or all selected stations will be
displayed in the Flow data fields. The Actual Flow will be displayed by
choosing Receive dur
ing oper
ation.
2
2
5
5