IV. ALARMS MENU
Master Minimum
Unexpected Flow
Over Flows
Over Currents
Clear Flow Alarms
Clear Fuse Alarms
Clear Map Alarms
Clear Power Fail
Note: The controller is capable of posting alarms when it detects excessive water flow or
excessive current.
Master Minimum
Selecting this menu item will display the status of the minimum flow alarm. The normal
status of this flag is off. It may be toggled on or off by using the Up and Down arrow
keys. If this flag displays ON, there has been a minimum flow alarm. Correct the problem
and set the flag to OFF. The minimum flow is necessary when the pump station requires
a minimum flow for cooling purposes. This alarm will turn off the master output to save
the pump from damage. The programs will continue to run. This alarm is operated by the
central system.
Unexpected Flow
Selecting this menu item will display the status of the unexpected flow alarm. The normal
status of this flag is off. It may be toggled to on or off by using the Up and Down arrow
keys. If this flag displays ON, there has been an unexpected flow condition. Correct the
problem if necessary and set the flag to OFF. This flag is set when the controller detects
flow while no station is running in the field controller.
Over Flows
Selecting this menu item will display the flow alarm status of the individual stations.
There must be a flow meter installed at the data retrieval port on the controller for this
feature function. If flow values have been properly set, the controller will watch the flow
as programs run. If there is a problem with a station such as broken line, broken heads,
etc., the controller will set the alarm for that station. If there are numerous stations
running at any one time and there is a flow problem with one station, the controller will
shut down the stations one at a time and check flow. This process will continue until the
malfunctioning station or stations are detected and disabled. Other stations that were
running will return to normal operation one at a time.
Use the Up and Down arrow keys to step through the stations and view or edit the ON or
OFF status of the flow alarms. The normal status is OFF. If the alarm status of a station is
ON, the station will not run in automatic mode.