Program ET Toggle
Set to ON for any programs you wish to run based on ET values, for time-based watering
set to OFF.
Station Type
The following station types are available:
UNIVRSAL – Use this option to turn on outputs locally and on a universal map to (when
mapped) (this is the default option)
LOCAL – Use this option to turn outputs on locally (out the front of the satellite).
BL-FL/PR – Not currently utilized. Baseline Flow & Pressure.
BL-SENS2 – Not currently utilized. Baseline Sensor.
BASELINE – Use this option to turn output on locally and on Baseline two-wire system.
TORO-2WD – Use this option to turn output on locally and on Toro two-wire system.
WIRELESS – Choose this option to run outputs on a wireless output board.
Map Stations
Each station can be mapped, or associated with hardware other than the Sentinel
controller output board. This setting relates to “Station Type” as set above.
Version 1.41 Firmware:
MAP 01 to 000:00
MAP SS to CCC:NN
LOCAL output:
No mapping necessary, any values entered are ignored.
UNIVERSAL output:
Setting for MapTo Universal,
Set PPP = 000
Set CCC = unit code of map to universal field unit
Set NN = map to universal output number
Version 1.42 Firmware:
01 -> 000/000:00
SS -> PPP/CCC:NN
Each station can be mapped, or associated with other hardware by way of the 8 numbers
to the right of the arrow. The fields labeled SS are the Sentinel station to be mapped (01-
96). The rest of the fields depend on the station type selected:
LOCAL output:
No mapping necessary, any values entered are ignored.
UNIVERSAL output:
Setting for MapTo Universal,
29