User's Manual

CLUSTER / SCHEDULE
SELECT Key
This button will be
described in more detail in
later parts of this guide.
Used for selecting Clusters
(groups of 4 programs) or
schedules (run days) when
programming.
PROGRAM SELECT Key
This button will be
described in more detail in
later pars of this guide.
Used for selecting the
Program (1-4) associated
with a Clusters when
programming.
Also included are four F-keys provided on the control module keypad to conveniently
perform the following functions:
F1 Key - Displays the time.
F2 Key - Displays the status of the automatic programs.
F3 Key - Shuts down anything that is running (panic button).
IMPORTANT: The F3 key is not functional while in the Edit mode.
F4 Key - Displays context sensitive help while in the Edit mode.
Sentinel Control Module Display
The Sentinel Controller has a two-line LCD for display of information. When you first
walk up to your Sentinel controller, the display should be in its standard mode showing
current time, day, week (of schedule), actual flow (if anything running) and expected
flow. This display should look something like the following:
This display (as shown) indicates:
Upper Line Lower Line
Time – 07:18 P (7:18 PM)
Day – MO (Monday)
Week (of schedule) – W1 (Week 1)
Sensor – No current sensor indication
Remote – L (Locked)
Actual Flow – 00000 (0 GPM)
Expected Flow – 00000 (0 GPM)
Flow Status – No current flow indicator
Alarm Status – A (Alarm Exists)
6