Outdoor Timer User Manual
Selecting Program Start Times
A program start time is the time of day you select to 
begin an automatic program watering cycle. 
It is important to remember that a program only 
requires one start time to operate automatically! 
When a program starts, each zone assigned to the 
program will water in numerical order, one at a time for 
its set run time. 
Sometimes it is necessary to run a watering program 
more than one time per day. For example, when germi-
nating a new lawn. The ECXTRA enables each program 
to have up to four separate start times per day. 
Program start times are numbered 1 through 4. These 
numbers are shown at the top left of the display next to 
the start time symbol when the control dial is in the
start time position and indicate how many start times 
are currently set for the program. 
This illustration shows how 
a program start time is dis-
played. In this example, 
program A has one start time 
(start time number 1) set 
for 3:00 am.
Setting the Zone Run Time
A zone run time is the length of time the zone (controlled 
by the valve) will water during the program watering 
cycle. The run time for each zone can be set from Off 
(no run time) to 4 hours, in one-minute increments. 
A zone is assigned to a program when it is given a run 
time. If the run time for a zone is turned Off in a program, 
it will not operate during the program watering cycle. 
This is how the ECXTRA enables you to assign zones to 
different programs.
Each zone can have a different run time assigned in each 
program. For example, zone 1 could be set to run for 15 
minutes in program A and 10 minutes in program B.
All zones assigned to the program are shown on the 
lower portion of the display when the control dial is in the
set zone times  position. 
This illustration shows how 
zone run time is displayed. In 
this example, zones 1–6 are 
assigned to program A. Zone 1 
has a 10-minute run time and 
zone 2 is set to run for 25 min-
utes. The zone run time being 
displayed is identified by the 
flashing zone number. Note the 
run time symbol is shown to 
indicate that zone run time is 
being set.
17
Flashing
Flashing