  Timer Installation
Note: The ECXTRA indoor timer is not weather resis-
tant and must be installed indoors or in a protected 
area. 
   Indoor Model Installation
1.  Select a location for the timer within 4′ (1,2m) of an 
electrical outlet to enable the transformer cord to 
easily reach. Make sure the outlet is not controlled 
by a light switch or used to power any large appliance 
such as a refrigerator, freezer, or air conditioner.
2.  Remove the mounting bracket attached to the back 
of the timer housing by pulling the lower edge of the 
bracket away and downward from the timer housing.
3.  Place the mounting bracket (A) against the wall 
aligning the top edge at about eye level. Drive two 
stainless steel screws (B) into the wall through two 
holes provided in the bracket. For additional stability, 
secure the bracket with three screws. 
  Note
: If you are installing the bracket on drywall or 
masonry, install screw anchors (C) to prevent screws 
from loosening. 
4. 
Optional - Insert 3/4″ (19mm) PVC conduit (D) for 
valve wiring into bracket sleeve (E).
5.  Align the slotted openings on the back of timer hous
-
ing with the mounting bracket tabs. Slide the timer 
downward to engage the tabs.
  Note: After installation, store the Quick Start Guide in 
the pocket (F) formed between the timer and bracket.
6
B
C
F
A
E
D 