User's Manual

Cabinet Dimensions:
• 10.5” W x 9.5” H x 5” D
Temperature Limits:
• Operating: +14°F to +140°F (-10°C to +60°C)
• Storage: -22°F to +149°F (-30°C to +65°C)
Power Specifications:
North America
Internal Transformer, Class 2, UL Listed, CSA Certified (or equivalent)
Input: 120 VAC ± 10%, 50/60 Hz
Output: 24 VAC ± 10%, 50/60 Hz, 30 VA
Europe and Australia
Internal Transformer, TUV Approved, SAA Approved
Input: 230 VAC ± 10%, 50/60 Hz
Output: 24 VAC ± 10%, 50/60 Hz, 30 VA
Maximum Load Per Station:
0.5A @ 24 VAC
Maximum Load Per Pump/Master Valve Circuit:
0.5A @ 24 VAC
Total Maximum Load:
1.20A @ 24 VAC
Surge Protection
• TSM-4 and TSM-8
6.0 KV common mode; 600 V normal mode
• TSM-4H, TSM-8H, TSM-4F and TSM-8F:
6.0 KV common mode; 6.0 KV normal mode
Battery Type:
• 9V Alkaline (not included)
Specifications
32