Operation Manual

45
CONTROLS AND FEATURES
English
NOTE: The adjustments made for Red / Green / Blue are
stored separately for each IRE setting. (There are ten IRE
settings from 10 to 100.)
Colour Calibration
The aim of Colour Calibration is to measure and/or adjust the
colour response (White Balance) of your LCD panel.
Colour Calibration is used by various fields, such as gaming,
photography, engineering, medical and more. In order to
calibrate a display correctly, you need a colour analyzer TPA-1
(not supplied).
NOTE: This feature is available when the Picture Mode option
is Hollywood Pro.
Apply Calibration
a In the Expert Picture Settings menu, press B or b to
select Colour Calibration and press OK.
b Press B or b to select Apply Calibration and press C
or
c to select Enabled.
Manual Colour Calibration
a In the Colour Calibration menu, press B or b to
select Manual Colour Calibration and press OK.
b Place the probe of the colour analyzer over the square
on screen to measure.
c Input the value measured with the colour analyzer
using the number buttons (0-9).
d Press BbC c and input the values to fill all RGBxy
matrix table.
e Highlight Start and press OK.
Please wait until you see “Manual Colour Calibration
has been completed.” on screen.
To return to factory setting
a Highlight Reset and press OK.
Auto Colour Calibration
a In the Colour Calibration menu, press B or b to
select Auto Colour Calibration and press OK.
b Connect the USB colour analyzer to the USB 1 or USB
2 port.
c Place the probe of the USB colour analyzer over the
square on screen and press OK.
Auto Colour Calibration will start.
Please wait until you see “Auto Colour Calibration has
been completed.”.
Gamma Calibration
a In the Expert Picture Settings menu, press B or b to
select Gamma Calibration and press OK.
b Press B or b to select Apply Calibration and press C
or
c to select Enabled.
c Press B or b to select Auto Gamma Calibration and
press OK.
d Connect the USB colour analyzer to the USB 1 or USB
2 port.
e Input the target value and place the USB colour
analyzer over the square on screen.
f Highlight Start and press OK.
Auto Gamma Calibration will start.
Please wait until you see “Auto Gamma Calibration
has been completed.” on screen.
To return to factory setting
a Highlight Reset and press OK.
Resetting to the factory defaults
a In the Expert Picture Settings menu, press B or b to
select Reset and press OK.
A confirmation screen appears.
b Select Yes and press OK.
Manual Colour Calibration
Red
0.642
x
y
0.277
0.143
0.335
0.603
0.067
Blue
Green
Start
Reset
Please input the value measured with the coulour analyser.
Red
0.642
x
y
0.277
0.143
0.335
0.603
0.067
Blue
Green
Auto Gamma Calibration
Target Colour Temperature
0.313
x
y
2.4
0.329
Target Gamma
Start
Reset
Please input the target value and place the USB colour analyser
over the square.