Datasheet

MATERIAL SAFETY DATA SHEET
MSDS No.
:
ODFC34YMCKPW1W
Product Identity
: 
OD-FC34K/OD-FC34Y/OD-FC34M/OD-FC34C (Drum included)
Page 2 of 4
SECTION 5 FIRE FIGHTING MEASURES
EXTINGUISHING MEDIA
:
CO2, Dry chemical, Foam or Water
SPECIAL FIRE-FIGHTING PROCEDURES
:
None
SECTION 6 ACCIDENTAL RELEASE MEASURES
PERSONAL PRECAUTIONS
:
None required under normal use.
ENVIRONMENTAL PRECAUTIONS
:
None required under normal use.
METHODS FOR CLEANING UP
:
Collect. No special precautions required in collection.
SECTION 7 HANDLING AND STORAGE
HANDLING
:
No special precaution. Do not touch the photoconductive layer directly,
expose to organic solvent vapor or sunlight to prevent degradation.
STORAGE
:
Store in normal temperature, normal humidity and dark place.
Avoid dew condensation, organic solvent vapor.
SECTION 8 EXPOSURE CONTROLS/PERSONAL PROTECTION
OCCUPATIONAL EXPOSURE LIMIT
:
ACGIH Not established.
OSHA Not established.
ENGINEERING MEASURES
:
No required.
PERSONAL PROTECTIVE EQUIPMENT
RESPIRATORY PROTECTION
:
None required.
EYE PROTECTION
:
Use safety glasses.
SKIN PROTECTION
:
No precautions.
SECTION 9 PHYSICAL AND CHEMICAL PROPERTIES
APPEARANCE AND ODOR
:
Green, odorless and solid cylinder.
DENSITY
:
2.7
VAPOR DENSITY
:
Not applicable.
BOILING POINT
:
Not applicable.
pH
:
Not applicable.
MELTING POINT
:
Not applicable.
LOG P o/w
:
Not applicable.
VAPOUR PRESSURE
:
Not applicable.
SOLUBILITY IN WATER
:
Insoluble.
SOLUBILITY IN OTHER SOLVENT
:
Photoconductive layer is soluble in organic solvent like Tetrahydrofuran.
FLASH POINT
:
Not applicable.
AUTOIGNITION TEMPERATURE
:
Not applicable.
FLAMMABLE LIMITS
:
Not applicable.