Datasheet

TOSHIBA TELECOM Mod 13 GS35F0099L
RCTUE3A DK424 Largest System Common Control Main Unit.
Used for spares or replacement. Supports Base Cabinet, and 1 to 6
Expansion Cabinets.
2,837.
RCTUF4A DK424 Largest System Common Control Sub Unit. Used for spares or replacement. 1 per RCTUE3A required.
4,657.
RDCC1A Remote Cabinet Daisy Chain Cable.
1 required at the intermediate site of a daisy chain configuration to connect
the S2 data cable from one RRCU to the M1 of the other.
107.
RDCL2A-M2 DK424 Remote Cabinet Data Cable M2. Connects M2 connector of an RRCU to a Data Highway Connector.
60.
RDCL2A-MS1 DK424 Remote Cabinet Data Cable M1/S1. Connects M1 or S1 connector of an RRCU to a Data Highway Connector.
86.
RDCL2A-S2 DK424 Remote Cabinet Data Cable S2. Connects S2 connector of an RRCU to a Data Highway Connector.
60.
RDDU2A 4-circuit analog Direct Inward Dialing Interface Unit
1 for each 4 DID line circuits. Requires K5RCU2 in DK40i and BRCS in
DK424i for DTMF operation. Primary protectors required. See General
Description for maximums. No ABR available.
420.
RDSU1A Digital/Standard Telephone Interface Unit. 1 per 4 digital station ports plus 2 standard station ports.
342.
RDTU3A T1/DS-1 Interface Unit.
Provides 24 channels for T1 Service on CTX670, CTX100 or DK424i, and 12-
channels on DK40i (requires R4.3). Network connection requires an external
CSU. Each RDTU3A requires 1 RDTU3-CBL-KIT cable kit.
899.
RDTU3-CBL-KIT T1 Interface Cable Kit for RDTU3A. 1 required for each RDTU3A. Not compatible with RDTU2A or RDTU1A.
60.
REMU1A 4-circuit analog Tie Line Interface Unit.
1 for each 4 E&M Tie line circuits (type 1 or 2, 2-wire or 4-wire). Requires
K5RCU2 on DK40i and BRCS on DK424i for DTMF operation. Primary
protectors required.
608.
RFDM1A External Microphone for the Full Duplex Speakerphone.
Optional for use with the DKT2020-FDSP to provide enhanced full duplex
microphone operation.
107.
RFIF1A DK424 Floor Mount Fixture Kit.
1 per DK424 system when floor mounted. Includes 3 pairs of wall securing
brackets for safety.
91.
RGLU3A 4-circuit Ground/Loop Start CO Line Interface Unit.
1 for each 4 ground start/loop start analog CO lines. Type of lines can be
mixed.
351.
RJ-AP11 ONEAC Analog Line Protector (1 pr,2 wire) modular.
Use for analog single line fax machines, modems, and telephones RJ11
connected (in/out) as required for lightning protection.
23.
RJ-AP14 ONEAC Analog Line Protector (2 pair,4 wire) modular.
Use for analog 2-line fax machines, modems, and telephones RJ14
connected (in/out) as required for lightning protection.
31.
RJ-AP45 ONEAC Analog Line Protector (4 pair,8 wire) modula.
Use for analog 4-line fax machines, modems, and telephones RJ61
connected (in/out) as required for lightning protection.
47.
RJ-DP11 ONEAC RJ11 Digital Line Protector (1 pr,2 wire) modular
Use for digital single line fax machines, modems, and telephones RJ11
connected (in/out) as required for lightning protection.
23.
RJ-DP14 ONEAC RJ14 Digital Line Protector (2 pr,4 wire) modular
Use for ISDN (2-pair) and digital 2-line modems, and telephones RJ14
connected (in/out) as required for lightning protection.
31.
RJ-DP45 ONEAC RJ45 Digital Line Protector (4 pr,8 wire) modular
Use for ISDN BRI (4-pair), digital 4-line modems, and telephones RJ61
connected (in/out) as required for lightning protection.
47.