MODE D’EMPLOI BEDIENUNGSANLEITUNG MANUALE DI ISTRUZIONI MANUAL DEL PROPIETARIO Ο∆ΗΓΙΕΣ ΧΡΗΣΕΩΣ MANUAL DO UTILIZADOR RAS-10JKVP-E / RAS-10JAVP-E RAS-13JKVP-E / RAS-13JAVP-E nchasing this TOSHIBA Air Conditioner. Please read this owner’s manual carefully before using your Air Conr. Thank you for purchasing this TOSHIBA Air Conditioner. Please read this owner’s manual carefully before using your Air Conditioner. Avant tout, merci d’avoir porté votre choix sur un climatiseur TOSHIBA.
RAS-10JKP_engTOC.fm Page i Thursday, December 26, 2002 6:10 PM FRANÇAIS ACCESSOIRES ..................................................................1 MESURES DE SECURITE..................................................1 NOM DES PIECES .............................................................3 NOM ET FONCTION DES TEMOINS ET COMMANDES DE L’UNITE INTERIEURE ..................................................3 TELECOMMANDE ET SES FONCTIONS .........................
01_EU_RAS-10JKP_EN.fm Page 1 Wednesday, April 9, 2003 8:08 AM Remote control holder Batteries (two) Zeolite-plus filter Zeolite-3G filter FRANÇAIS Remote control ENGLISH AIR FILTER COMPONENTS ACCESSORIES SAFETY PRECAUTIONS DANGER DEUTSCH • DO NOT ATTEMPT TO INSTALL THIS UNIT BY YOURSELF. THIS UNIT REQUIRES A QUALIFIED INSTALLER. • DO NOT ATTEMPT TO REPAIR THE UNIT BY YOURSELF. THIS UNIT HAS NO COMPONENTS WHICH YOU CAN REPAIR. • OPENING OR REMOVING THE COVER WILL EXPOSE YOU TO DANGEROUS VOLTAGES.
01_EU_RAS-10JKP_EN.fm Page 2 Wednesday, April 9, 2003 8:08 AM CAUTION . INSTALLATION CAUTIONS • Securely lay the drain hose for the best draining results. • Incorrect drainage can cause flooding in the house and furniture to get wet. • Be sure to connect the air conditioner to a dedicated power supply having the rated voltage. Otherwise, the unit can break down or cause a fire. • Do not install the unit in a place where inflammable gas can leak.
01_EU_RAS-10JKP_EN.
01_EU_RAS-10JKP_EN.fm Page 4 Wednesday, April 9, 2003 8:08 AM REMOTE CONTROL AND ITS FUNCTIONS a Infrared signal transmitter Transmits signals to the indoor unit. n Automatic operation button (AUTO) Press this button to operate the air conditioner automatically. (A receiving beep is heard.) () see page 16.) o Economy button (ECO) Press this button to operate the air conditioner economically. () see page 16.) p FILTER button Press this button to turn off the filter cleaning indicator on the indoor unit.
01_EU_RAS-10JKP_EN.fm Page 5 Wednesday, April 16, 2003 4:16 PM All indicators, except for the clock time indicator, are displayed by pressing the button. a Transmission mark This transmission mark ( ) indicates when the remote control transmits signals to the indoor unit. b Mode indicator adb hj c Indicates the current operation mode. (AUTO: Automatic control, A: Auto changeover control, : Cool, : Dry, : Heat) c Temperature indicator Indicates the temperature setting (17°C to 30°C).
01_EU_RAS-10JKP_EN.fm Page 6 Wednesday, April 9, 2003 8:08 AM Setting the clock Before you start operating the air conditioner, set the clock of the remote control using the procedures given in this section. The clock panel on the remote control will indicate the time regardless of whether the air conditioner is in use or not. Initial setting When batteries are inserted in the remote control, the clock panel displays AM 0:00 and flashes.
01_EU_RAS-10JKP_EN.fm Page 7 Wednesday, April 9, 2003 8:08 AM ENGLISH USING THE REMOTE CONTROL CAUTION FRANÇAIS • The air conditioner will not operate if curtains, doors or other objects block the signals from the remote control to the indoor unit. • Be careful that liquids do not spill onto the remote control. Do not expose the remote control to direct sunlight or heat. • If the infrared signal receiver on the indoor unit is exposed to direct sunlight, the air conditioner may not function properly.
01_EU_RAS-10JKP_EN.fm Page 8 Wednesday, April 9, 2003 8:08 AM AUTOMATIC OPERATION When you set the air conditioner to AUTO mode, it automatically selects cooling, heating, or fan only operation depending on the room temperature. () see page 16.) The fan speed and louver are also automatically controlled. Start a button Press this button to start the air conditioner. b AUTO button (AUTO) Press AUTO button. • The OPERATION indicator (green or orange) on the display panel of the indoor unit lights.
01_EU_RAS-10JKP_EN.fm Page 9 Wednesday, April 9, 2003 8:08 AM ENGLISH COOLING/HEATING OPERATION Start a button Press this button to start the air conditioner. b Mode select button (MODE) Select Cool or Heat . , MED , MED+ , AUTO PAP • The OPERATION indicator (green or orange) on the display panel of the indoor unit turns on. Operation starts after approximately 3 minutes. c b a Stop d button Press this button again to stop the air conditioner. TEMP PRESET MODE HiPOWER ECO MEMO 1.3.5.
01_EU_RAS-10JKP_EN.fm Page 10 Wednesday, April 9, 2003 8:08 AM AIR PURIFYING OPERATION During air conditioner operation a PAP button Pressing this button starts Plasma Air Purifying (PAP) operation. • The PLASMA indicator (blue) on the display panel of the indoor unit turns on. • Plasma pure filter and air ionizer are activated. To stop only PAP operation PAP button Pressing this button stops PAP operation. • The PLASMA indicator (blue) on the display panel of the indoor unit turns off.
01_EU_RAS-10JKP_EN.fm Page 11 Wednesday, April 9, 2003 8:08 AM ENGLISH Hi POWER OPERATION High power (Hi POWER) • The Hi POWER (high power operation) mode automatically controls room temperature, air flow and the operation mode so that the room is quickly cooled in summer and warmed in winter. () see page 16.) Setting Hi POWER mode a Hi POWER button Press the Hi POWER button. The Hi POWER mark on the remote control is shown. a Hi POWER button Press the Hi POWER button once again.
01_EU_RAS-10JKP_EN.fm Page 12 Wednesday, April 9, 2003 8:08 AM Combined timer (Setting the ON and OFF timers simultaneously) OFF timer —> ON timer (Operation —> Stop —> Operation) This feature is useful when you want to stop the air conditioner after you go to sleep, and start it again in the morning when you wake up or you return home. Example: To stop the air conditioner and start it again next morning Setting combined TIMER (1) Press the OFF Operation again Operation button to set the OFF timer.
01_EU_RAS-10JKP_EN.fm Page 13 Wednesday, April 9, 2003 8:08 AM ENGLISH MEMORY/PRESET OPERATION AUTO PAP TEMP MODE a b PRESET HiPOWER ECO MEMO 1.3.5.9H SWING FIX FAN SLEEP OFF FILTER CLR CLOCK SET ON DEUTSCH b MEMO button Hold down the MEMO button for more than 3 seconds while the indicator flashes. The mark is shown and the setting is stored. • If you do not press the MEMO button within 3 seconds or if you press another button, the MEMORY setting is cancelled.
01_EU_RAS-10JKP_EN.fm Page 14 Wednesday, April 9, 2003 8:08 AM ADJUSTING AIR FLOW DIRECTION • Adjust the air flow direction properly. Failure to do so could cause discomfort and make an uneven room temperature distribution. • Adjust the vertical air flow using the remote control. • Adjust the horizontal air flow manually. Adjusting the vertical air flow The air conditioner automatically adjusts the vertical air flow direction according to the operating conditions when AUTO or A mode is selected.
01_EU_RAS-10JKP_EN.fm Page 15 Wednesday, April 9, 2003 8:08 AM This air conditioner is equipped with an automatic restarting function which allows the air conditioner to resume without the use of the remote control under the operating settings in the event of a power shutdown. Operation resumes without warning three minutes after power is restored. ENGLISH AUTO RESTART OPERATION To set the auto restart function, proceed as follows: The power supply to the unit must be on.
01_EU_RAS-10JKP_EN.fm Page 16 Wednesday, April 9, 2003 11:23 AM HOW THE AIR CONDITIONER WORKS Automatic Operation As shown in Figure 1, Automatic Operation mode selects the operation based on the room temperature data (Ta) when operation begins. Room temperature when operation begins or when selected again Ta Ts+1 Ts Ts–1 Cooling operation Fan operation Heating operation Figure 1 The operation mode is selected again after the compressor has remained stopped for 15 minutes.
01_EU_RAS-10JKP_EN.fm Page 17 Wednesday, April 9, 2003 11:23 AM ) ENGLISH DRY operation ( The dry mode automatically selects the cooling dry operation based on the difference between the temperature setting and the actual room temperature. The fan speed indicator shows AUTO, and low speed is used. HINTS FOR ECONOMICAL OPERATION FRANÇAIS Chilly Maintain room temperature at a comfortable level Control Clean the air filters Clogged air filters impair the performance of the air conditioner.
01_EU_RAS-10JKP_EN.fm Page 18 Wednesday, April 9, 2003 8:08 AM USUAL MAINTENANCE WARNING Before you clean the air conditioner, be sure to turn off the circuit breaker or main power switch. Cleaning of indoor unit and remote control Wipe with a dry cloth CAUTION • Use a dry cloth to wipe the indoor unit and remote control. • When the air conditioner is extremely dirty, use a cloth dipped in cold water to wipe the indoor unit. • Never use a damp cloth on the remote control.
4 Insert the top section of the air filter so that its right and left edges fit on the indoor unit and it is firmly set. 5 Close the air inlet grille. * If the FILTER indicator on the indoor unit is shown, press the FILTER button on the remote control or the RESET button on the indoor unit to turn off the indicator. ENGLISH 01_EU_RAS-10JKP_EN.fm Page 19 Wednesday, April 9, 2003 8:08 AM Filter holder Preparation: 1. Turn off the air conditioner using the remote control. 2. Open the air inlet grille.
01_EU_RAS-10JKP_EN.fm Page 20 Wednesday, April 9, 2003 8:08 AM SPECIAL MAINTENANCE Attaching the Zeolite-plus filter and Zeolite-3G filter • After installing the air conditioner, attach the supplied Zeolite-plus filter and Zeolite-3G filter. Preparation: 1. Turn off the air conditioner using the remote control. INFORMATION • It is recommended that you replace the filters once about every six years.
01_EU_RAS-10JKP_EN.fm Page 21 Wednesday, April 9, 2003 8:08 AM ENGLISH Cleaning the air ionizer • Clean the air ionizer when you clean the dust collecting unit. (Clean approximately once every six months.) Preparation: 1. Turn off the air conditioner using the remote control. 2. Turn off the power supply. FRANÇAIS WARNING Touching the ends of the metal pins inside the air ionizer (dark blue) can result in an electrical shock. 1 2 Fully open the vertical air flow louvers by hand.
01_EU_RAS-10JKP_EN.fm Page 22 Wednesday, April 9, 2003 8:08 AM 4 Wash and then dry. (1) Soak in hot water at 40 to 50°C for about 10 to 15 minutes. If the staining is particularly severe, use a washing detergent compound (weak basic or neutral) at 10 to 15 times the standard concentration. (2) Rub up and down, and rub left and right. Also, rub the surface gently with a sponge. (3) Rinse with running water. (4) Shake thoroughly, and allow the unit to drain.
01_EU_RAS-10JKP_EN.fm Page 23 Wednesday, April 9, 2003 8:08 AM Three-minute protection feature A protection feature is provided that prevents the air conditioner from being activated for approximately 3 minutes when it is restarted immediately after operation or when the power supply switch is set to on. This is used to protect the machine.
01_EU_RAS-10JKP_EN.fm Page 24 Wednesday, April 9, 2003 8:08 AM TROUBLESHOOTING CAUTION If any of the following conditions occur, stop the air conditioner immediately, turn off the main power switch and contact the dealer. • The indicators flash at short intervals (5 Hz). Reset the circuit breaker 2 to 3 minutes after the power main switch is turned off. Despite the resetting operation, the indicators still continue turning on and off. • Switch operation is erratic.
01_EU_RAS-10JKP_EN.fm Page 25 Wednesday, April 9, 2003 8:08 AM Before asking for servicing or repairs, check the following points. ENGLISH Condensation forms on the back of the indoor unit. • Condensation on the back of the indoor unit is automatically collected and drained out. FRANÇAIS Indoor unit or outdoor unit makes a strange noise.
01_EU_RAS-10JKP_EN.fm Page 26 Wednesday, April 9, 2003 8:08 AM Before asking for servicing or repairs, check the following points. The FILTER indicator turns on. • This indicator turns on after PAP operation has been performed for approximately 1000 hours. • The indicator may turn on if the front panel is not firmly closed. • The indicator may turn on if the dust collecting unit is not securely attached.
01_EU_RAS-10JKP_EN.fm Page 27 Wednesday, April 9, 2003 8:08 AM Type Reverse cycle, Split type Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit RAS-10JKVP-E RAS-10JAVP-E RAS-13JKVP-E RAS-13JAVP-E 220 – 240 V~, 50 Hz 220 V~, 60 Hz 220 – 240 V~, 50 Hz 220 V~, 60 Hz Cooling capacity (kW) CAPA. 2.5 3.5 Heating capacity (kW) CAPA. 3.2 4.2 Cooling current (A) AMP 0.15 2.58 – 2.35 0.15 4.40 – 4.02 Cooling power (W) WATT. 30 540 30 920 Heating current (A) AMP. 0.15 3.44 – 3.
01_EU_RAS-10JKP_EN.fm Page 28 Wednesday, April 9, 2003 8:08 AM TROUBLESHOOTING (Remote Control) Before asking for servicing or repairs, check the following points. Settings Cannot be Changed Symptoms The fan speed cannot be changed. Causes Description and Remedy • Check whether the MODE indicated on the display is “AUTO”. When automatic mode is selected, the air conditioner automatically selects the fan speed. AUTO • Check whether the MODE indicated on the display is “ : DRY”.
RAS-10JKP-backCV.fm Page 1 Wednesday, April 9, 2003 12:02 PM DECLARATION OF CONFORMITY We, TOSHIBA CARRIER CORPORATION, 336 Tadewara, Fuji-shi, Shizuoka-ken, 416-8521, Japan, declare under our responsibility that the product, Household split type Room Air Conditioner, to which this declaration relates is in conformity with the provisions of Council Directive 89/336/EEC Electromagnetic Compatibility and 73/23/EEC Low Voltage Directive.