9-3. Error Mode Detected by LED on Outdoor P.C. Board
RAV-SP562AT-E only
<SW801: LED display in bit 1, bit 2 OFF>
When multiple errors are detected, the latest error is displayed.
When LED display is
¡
(Go on), there is the main cause of trouble on the objective part of control at CDB
side and the unit stops.
When LED display is
¥
(Flash), there is the main cause of trouble on the objective part of control at IPDU
side and the unit stops.
When case thermostat operates, the communication is interrupted on the serial circuit.
If continuing the case thermostat operation, a serial communication error occurs because serial sending to
the indoor unit is interrupted.
CDB side
IPDU side
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Item
TE sensor error
TD sensor error
TS sensor error
TO sensor error
Discharge temp. error
DC outdoor fan error
Communication error between IPDU
(Abnormal stop)
High-pressure release operation
EEPROM error
Communication error between IPDU
(No abnormal stop)
IGBT short-circuit protection
Detection circuit error
Current sensor error
Comp. lock error
Comp. breakdown
Check
code
Type A
F06
F04
F06
F08
P03
P22
L29
P04
P26
P29
H03
H02
H01
LED display
D800 D801 D802 D803
(Red) (Yellow) (Yellow) (Yellow)
¡
lll
¡¡
ll
ll
¡
l
l
¡
ll
l
¡¡
l
¡¡¡
l
¡
ll
¡
l
¡
l
¡
¡¡
l
¡
ll
¡¡
¥
lll
l
¥
ll
¥¥
ll
ll
¥
l
¥
l
¥
l
¡
: Go on
l
: Go off
¥
: Flash (5Hz)
<<Check code>>
The check codes are classified into Type A and Type B according to the used remote controller.
Be sure to check the remote controller which you use.
Type A :
Neutral 2-cores type wired remote controller such as RBC-AMT31E, RBC-AMT32E, RBC-AS21E2,
and wireless remote controller kit such as TCB-AX21E2