user manual

8
<Triple type>
Indoor unit 1 RAV-SM562MUT-E
Model
Indoor unit 2 RAV-SM562MUT-E
Indoor unit 3 RAV-SM562MUT-E
Outdoor unit RAV-SM1603AT-E
Cooling capacity (kW) 14.0
Heating capacity (kW) 16.0
Indoor unit
Power supply 1 phase 230V (220 240V) 50Hz
Running current (A) 23.88 21.89
Power consumption (kW) 4.99
Cooling Power factor (%) 95
EER 2.81
Electrical
Energy efficiency class C
characteristics
Running current (A) 22.44 20.57
Power consumption (kW) 4.69
Heating Power factor (%) 95
COP 3.41
Energy efficiency class B
Fan Turbo fan
Fan unit Standard air flow H/M/L (m³/min.) 13.3 / 11.2 / 9.1
Motor (W) 60
Sound pressure level H/M/L (dBA) 43 / 39 / 34
Sound power level H/M/L (dBA) 58 / 54 / 49
Outdoor unit
Power supply 1 phase 230V (220 240V) 50Hz
Standard length (m) 7.5
Min. length (m) 5.0
Outer dimension Max. total length (m) 50
Height
Outdoor lower (m) 30
difference
Outdoor higher (m) 30
Fan Propeller fan
Fan unit Standard air flow volume (m³/min.) 103
Motor (W) 100 + 100
Gas side
Main (mm) 15.9
Connecting pipe
Sub (mm) 12.7
Liquid side
Main (mm) 9.5
Sub (mm) 6.4
Sound pressure level Cooling/Heating (dBA) 51 / 53
Sound power level Cooling/Heating (dBA) 68 / 70
: IEC standard