Strata CTX100-S/CTX100 Installation
Site Requirements
3-2 Strata CTX I&M 06/04
The AC outlet is recommended to be dedicated and unswitched, with a solid third-wire ground.
(See “AC Power and Grounding Requirements” on page 3-4.) This eliminates interference from
branch circuit motor noise or the like, and to prevent accidental power-off. To avoid accidental
power turn-off, Toshiba recommends that you do not use an On/Off wall switch on this dedicated
AC circuit.
For the Strata CTX100, a reserve power source (two or four customer-supplied 12VDC batteries)
may be connected to the system to serve as a power failure backup.
Cabinet Size and Weight
The wall that will support the CTX100 should be able to support 35 lbs. The weight of each
cabinet is shown in Table 2-1 on page 2-2.
Clearance and Location
The minimum clearance requirements for the Strata CTX100 Base and Expansion cabinets are
shown in Figure 3-1.
Consider the following conditions when selecting a location for the Cabinet(s):
The location must be:
Dry and clean
Well ventilated
Well illuminated
Easily accessible
The location must not be:
Subject to extreme heat or cold
Subject to corrosive fumes, dust, or other airborne contaminants
Subject to excessive vibration
Next to television, radio, office automation, or high frequency equipment
If reserve power is to be installed for the Strata CTX100, the batteries will require a well-
ventilated location close (within nine feet) to the CTX100 (the optional Toshiba-supplied battery
cable is nine feet in length).