Step 6: Connect Data and Ground Cables
Strata CTX I&M 06/04 5-11
Rack Mount Cabinets
Step 6: Connect Data and Ground Cables
1. Wire the data cable between the base and expansion cabinet (shown below).
2. Wire the FG cable between the base and expansion cabinet by passing it through the hole in the
base of the expansion cabinet. Secure the FG wire spade lug to the power supply with the FG
screws (as shown below).
Note The backplane FG wires are not safety grounds: they are required for proper system CO line
operation.
7007
CAB
2
CAB
5
CAB
6
CAB
7
CAB
3
CAB
4
CAB 2 CAB 3 CAB 4
View from Top
To MS B U
of respective
Exp. Cabinet
CAB 7
CAB 6
CAB 5
Back View
Base Cabinet
Data Cable
6985
Back View Base Cabinet
Screw FG Cable
from upper cabinet
Screw FG Cable
from lower cabinet
Pass FG Cable
through this Hole
6987a
FG Cable
6986a
Front View