Manual

Parameter detail > 12
For an illustration of how to insert these parameters see “Data for UPC–A barcode printing
(example 2)” on page 14.
S-
PARAMETER
Specifies the width of spaces (white bars) in units of 1/600 inch. Usage is exactly the same
as for the B-parameter. Refer to “B-parameter” on page 11.
D
EFAULT
PARAMETER
VALUES
If parameters are omitted or invalid their default values are assumed. These vary
depending on the barcode type selected with the T-parameter. Default values for each
barcode type are listed in the following table.
* For ZIP+4 POSTNET no human readable text is printed, and bar width and height are fixed. These items
do not therefore require parameters. If supplied, they are ignored.
BARCODE P V B/S
#1 #2 #3 #4
UPCA 3 748 162432
UPCE 3 298 162432
EAN/JAN8 3 508 163432
EAN/JAN–13 3 74 8 16 24 32
Interleaved 2of5 1 29 6 18
Code39 1 29 6 18
Code128 1 29 6 12 18 24
EAN/UCC–128 1 29 6 12 18 24
CODABAR 1 29 6 18
ZIP+4 POSTNET***–––