GPS RECEIVER UNIT INSTRUCTION MANUAL HHGP1

16
6 F 2 S 0 7 3 8
6.6 Connecting the Power Supply and the Earthing Terminal
Connect the 48Vdc power cable and the earth cable to the terminal block with M4 crimped
terminals. For safety purposes, make sure that the earth connection is reliable.
CAUTION
The earthing terminal must be securely earthed. The failure to ground may cause
malfunctions, electric shocks or injury.
Figure 6.6.1 External Connection of GPS Receiver Unit
Fibre optic cable to relay
Earth
Earth
(Earth the arrester only.)
Antenna
Adapter
Adapter
Co - axial cable
Co - axial cable
Arrester
P
N
48V
E