Safety Precautions Operating Ins Instructions Installation Instructions Care C Cleaning are and Clea Troubleshooting Tips Troubleshoot Remote Control Operating Instructions USER MANUAL Portable Type Room Air Conditioner RAC-PD0811CRU RAC-PD1011CRU RAC-PD1211CRU RAC-PD1411CRU RAC-PD1411CWU RAC-PD1411HRU version B - 10 - 2017 Warning notices: Before using this product, please read this manual carefully and keep it for future reference.
User Manual Safety Precautions ...................................................................................................... 3 Operating Instructions .............................................................................................. 5 Installation Instructions ......................................................................................... 11 Care and Cleaning ...................................................................................................
SAFETY PRECAUTIONS WARNING: This symbol indicates the possibility of death or serious injury. CAUTION: This symbol indicates the possibility of injury or damage to property. WARNING Please read through these instructions before you start the installation process. Improper installation can cause damage to the unit, your personal property, and also poses a personal safety hazard. • Installation must be performed according to the installation instructions.
WARNING • DO NOT allow children to play with the air conditioner. Children must be supervised around the unit at all times. Safety Precautions • If the air conditioner is knocked over during use, turn off the unit and unplug it from the main power supply immediately. Visually inspect the unit to ensure there is no damage. If you suspect the unit has been damaged, contact a technician or customer service for assistance.
OPERATING INSTRUCTIONS Preparation control panel horizontal louver blade (automatic swing) handle upper air filter (behind the grille) Operating Instructions (both sides) upper air intake Panel drain outlet air outlet lower air filter lower air intake drain outlet (only for pump heating mode) power cord outlet power cord buckle Caster Front power plug socket bottom tray drain outlet Rear Design and Compliance Notes Design Notice: In order to ensure the optimal performance of our products, the
Control Panel Features LED Display Wi-Fi Indicator Light (Wi-Fi models only) Operating and Features Instructions Swing Button Timer Button Mode Button Up ( ) and Down ( Buttons ) Fan Button Sleep/Eco Button Power Button Swing Button Mode button Used to initiate the Auto Swing feature. When the operation is ON, pressing the SWING button can stop the louver at the desired angle. Selects the desired operating mode.
Control Panel Features (cont.) Wi-Fi Indicator Light (Wi-Fi models only) LED Display Operating Instructions Swing Button Timer Button Mode Button Up ( ) and Down ( Buttons ) Fan Button Sleep/Eco Button Power Button WI-FI Function LED display (Available on Wi-Fi models only) Shows the set temperature in °C (Degrees Celsius) or °F (Degrees Fahrenheit) and the Auto-timer settings. While on DRY and FAN modes, it shows the room temperature.
Operating Instructions COOL operation • • • Operating Instructions Press the “MODE” button until the “COOL” indicator light comes on. Press the ADJUST buttons Up ( ) or Down ( ) to select your desired room temperature. The temperature can be set within a range of 17°C~30°C/62°F~86°F. Press the “FAN SPEED” button to choose the fan speed. • Press the “FAN SPEED” button to choose the fan speed. The temperature cannot be adjusted. • Do not connect the duct to a window.
Other Features AUTO-RESTART If the unit shuts off unexpectedly due to a power outage, it will restart with the previously set function automatically when the power resumes. WAIT 3 MINUTES BEFORE RESUMING OPERATION AIRFLOW DIRECTION ADJUSTMENT The louver can be adjusted automatically. Adjust the airflow direction automatically. • When the Power is ON, the louver opens fully. • Press the SWING button on the panel or remote controller to initiate the Auto Swing feature.
NOTE Make sure the hose is secure so there are no leaks. Direct the hose toward the drain, making sure that there are no kinks that will impede water flow. Place the end of the hose into the drain and make sure ). the end of the hose is directed downward to let the water flow smoothly. (See Figs with Operating Instructions delivery lift <1.8m Installation not recommended. (See Figs with X ).
INSTALLATION INSTRUCTIONS Choosing the Right Location Your installation location should meet the following requirements: Make sure that you install your unit on an even surface to minimize noise and vibration. • The unit must be installed near a grounded plug, and the Collection Tray Drain (found on the back of the unit) must be accessible. • The unit should be located at least 30 cm (12”) from the nearest wall to ensure proper air conditioning.
Tools Needed • Medium Phillips screwdriver • Tape measure or ruler • Knife or scissors • Saw (optional, to shorten window adaptor for narrow windows). Accessories Your Window Installation Kit fits windows 67.5-123 cm (26.5”-48”) and can be shortened for smaller windows.
Window Installation Kit Exhaust hose Exhaust hose assembly Step One: Preparing the exhaust hose assembly Press the exhaust hose into the window slider adaptor and unit adaptor, clamp automatically by elastic buckles of the adaptors. Unit adaptor Window slider adaptor Step Two: Install the exhaust hose assembly to the unit Hook Hole Seat Adaptor Lower groove Make sure the adaptor is inserted into the lower groove of the air outlet.
NOTE Once the Exhaust Hose assembly and Adjustable Window Slider are prepared, choose from one of the following two installation methods. Foam seal B (Adhesive type-shorter) Type 1: Hung window installation 1. Cut the adhesive foam seal A and B strips to the proper lengths, and attach them to the window sash and frame as shown. 2. Insert the window slider assembly into the window opening. 3. Cut the non-adhesive foam seal C strip to match the width of the window.
Foam seal B (Adhesive type-shorter) Type 2: Sliding window installation 1. Cut the adhesive foam seal A and B strips to the proper lengths, and attach them to the window sash and frame as shown. 2. Insert the window slider assembly into the window opening. 3. Cut the non-adhesive foam seal C strip to match the window height. Insert the foam seal between the glass and the window frame to prevent air and insects from getting into the room. 4.
CARE AND CLEANING Safety Precautions • Always unplug the unit before cleaning or servicing. • DO NOT use flammable liquids or chemicals to clean the unit. • DO NOT wash the unit under running water. Doing so causes electrical danger. • DO NOT operate the machine if the power supply was damaged during cleaning. A damaged power cord must be replaced with a new cord from the manufacturer.
TROUBLESHOOTING TIPS Malfunction Diagnosis Please check the machine according to the following table before calling for service: Problem Troubleshooting P1 Error Code. The water collection tray is full. Turn off the unit, drain the water from the water collection tray and restart the unit. In COOL mode: room temperature is lower than the set temperature. Reset the temperature. The air filter is blocked with dust or animal hair. Turn off the unit and clean the filter according to instructions.
REMOTE CONTROL OPERATING INSTRUCTIONS Remote Control Specifi cations Model Rated voltage Signal receiving range Environment RG57H(B)/BGCEU1 RG57H(B)/BGEU1 3.0V (Dry batteries R03/LR03x2) 8 m (approx. 26 ft.) -5°C ~ 60°C (23°F ~ 140°F) Function Buttons Before you begin using your new air conditioner, make sure to familiarize yourself with its remote control. The following is a brief introduction to the remote control itself.
Handling the Remote Control NOT SURE WHAT A FUNCTION DOES? Refer to the Operating Instructions section of this manual for a detailed description of how to use your air conditioner. SPECIAL NOTE Button designs on your unit may differ slightly from the example shown. If the unit does not have a particular function, pressing that function’s button on the remote control will have no effect.
Remote LED Screen Indicators Transmission Indicator Lights up when remote sends signal to unit MODE display Displays the current mode, including: ON/OFF display Appears when the unit is turned on and disappears when it is turned off AUTO COOL DRY HEAT FAN TIMER ON display Displays when TIMER ON is set TIMER OFF display Displays when TIMER OFF is set ECO display Not available on this unit Battery display Low battery detection SLEEP display Displays when SLEEP function is activated FOLLOW ME display Not a
Basic Functions SETTING THE DESIRED TEMPERATURE The operating temperature range for this unit is 17-30°C (62°F-86°F). You can increase or decrease the set temperature in 1°C (1°F) increments. 3 1 2 AUTO operation In AUTO mode, the unit will automatically select the COOL, FAN, HEAT or DRY mode based on the set temperature. 1. Press the MODE button to select Auto mode. 2. Set your desired temperature using the Temp button. or Temp 3. Press the ON/OFF button to start the unit.
FAN operation 1. Press the MODE button to select FAN mode. 2. Press FAN button to select the fan speed: AUTO, LOW, MED or HIGH. 3. Press the ON/OFF button to start the unit. 3 1 NOTE 2 You cannot set temperature in FAN mode. As a result, your remote control’s LCD screen will not display temperature. HEAT operation 1. Press the MODE button to select HEAT mode. 2. Set your desired temperature using the Temp button. 4 1 3 2 or Temp 3.
Timer Functions 1 2 TIMER ON x5 TIMER ON Your air conditioning unit has two timer-related functions: TIMER ON - sets the amount of time after which the unit will automatically turn on. TIMER OFF - sets the amount of time after which the unit will automatically turn off. TIMER ON function 3 1sec 4 2sec The TIMER ON function allows you to set a period of time after which the unit will automatically turn on, such as when you come home from work. 1. Press the TIMER ON button.
3. Wait 2 seconds, then the TIMER OFF function will be activated. The digital display on your remote control will then return to the temperature display. T imer on NOTE Continue to press TIMER ON or TIMER OFF until desired time is reached. 1 2 TIMER ON X12 When setting the TIMER ON or TIMER OFF functions, up to 10 hours, the time will increase in 30 minute increments with each press. After 10 hours and up to 24, it will increase in 1 hour increments. The timer will revert to zero after 24 hours.
How to Use the Advanced Functions SLEEP Function The SLEEP function is used to decrease energy use while you sleep (and don’t need the same temperature settings to stay comfortable). This function can only be activated via remote control. Note: The SLEEP function is not available in FAN or DRY mode. SWING Function Used to stop or start louver movement and set the desired up/down air flow direction. The louver angle changes in 6 degree increments with each press (not all models).
NOTES • The device may comply with local national regulations. In Canada, it should comply with CAN ICES-3(B)/NMB-3(B). In USA, this device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
WARNING: Chemical Burn Hazard. Keep batteries away from children. This product contains a lithium button/coin cell battery. If a new or used lithium button/coin cell battery is swallowed or enters the body, it can cause severe internal burns and can lead to death in as little as 2 hours. Always completely secure the battery compartment. If the battery compartment does not close securely, stop using the product, remove the batteries, and keep it away from children.